期刊文献+

利用微型氡室模拟环境变化对氡浓度测量结果的影响

Impact of Simulating Environmental Change in Micro Radon Chamber on the Measurement Results of Radon Concentration
下载PDF
导出
摘要 本文通过对微型氡室进行加温、加湿和加气溶胶模拟测试环境,研究环境温度,湿度和气溶胶对氡浓度的影响,并对结果进行分析.结果表明:温度对氡浓度的影响很小;在20%~50%的湿度范围内,氡浓度随着湿度的增加而呈指数增长;且在一定的压强范围内,氡浓度随着气溶胶浓度的增加也呈指数增长. This paper studies the effects of environmental temperature, humidity and aerosol on the test results through simulating the test conditions by warming, humidifying and aerating sol-gel the micro radon chamber, as well as we analyz our results. It indicates that temperature has little influence on the results. Radon concentrations increase with the increase of the humidity by exponentially when the concentrations of humidity range from 20% to 50%, and within certain scope of pressure, the concentrations of radon also increase with the increase of the aerosol by exponentially.
出处 《新疆大学学报(自然科学版)》 CAS 2011年第3期352-354,共3页 Journal of Xinjiang University(Natural Science Edition)
关键词 微型氡室 温度 湿度 气溶胶 micro radon chamber temperature humidity aerosols