摘要 一体式PET/MRI较其他多模态成像,如PETCT等具有明显的优点:同步采集、无射线危害、高软组织对比度,可实现各种功能成像等。一体式PET/MRI技术具有许多难点,如磁兼容性问题、PET和MRI的互相干扰问题,磁共振孔径有限等。一体式PET/MRI采用的技术包括基于光纤式、基于APD传感器式等,其中,APD传感器对设计全身临床型一体式PET/MRI更有前途。目前,一体式动物PET/MRI已应用较多,但临床型一体式PET/MRI尚处于初期发展阶段,不过初步的临床应用揭示PET/MRI对临床医学成像具有重要意义。 Compared with other multi-modality imaging methods like PET/CT,the integrated PET/MRI has many obvious advantages,such as simultaneous acquisition,no radiation hazards,higher soft tissue contrast,various functional imaging.Integrated PET/MRI technology encountered many challenges,such as magnetic compatibility issues,mutual interference problems,and limited magnetic resonance aperture.Integrated PET/MRI uses technologies,such as fiber-based type,APD sensor type,etc.The APD sensor seems more valuable for designing a clinical whole-body Integrated PET/MRI.Currently integrated animal PET / MRI has been used more often,but the clinical type of integrated PET / MRI is still in the early stages of development,however,reveals preliminary clinical application of PET / MRI imaging of clinical significance.
出处 《中国医疗设备》 2011年第8期54-57,62,共5页 China Medical Devices
关键词 磁共振成像 PET 多模态成像 雪崩光电二极管 功能成像 MRI PET multi-modality imaging APD functional imaging
  • 相关文献

参考文献28

  • 1Heinz-Peter Schlemmer,Bernd J. Pichler,Robert Krieg,Wolf-Dieter Heiss.An integrated MR/PET system: prospective applications[J]. Abdominal Imaging . 2009 (6)
  • 2Fritz Schick.Whole-body MRI at high field: technical limits and clinical potential[J]. European Radiology . 2005 (5)
  • 3Sibylle I. Ziegler,Bernd J. Pichler,Guido Boening,Magdalena Rafecas,Wendelin Pimpl,Eckart Lorenz,Norbert Schmitz,Markus Schwaiger.A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals[J]. European Journal of Nuclear Medicine and Molecular Imaging . 2001 (2)
  • 4Pichler BJ,Judenhofer MS,Catana C,et al.Performance Test ofa LSO-APD PET Module in a 9.4 Tesla Magnet. IEEE NuclSci Symp Med Imaging Conf . 1998
  • 5Raylman RR,Majewski S,Velan SS,et al.Simultaneousacquisition of magnetic resonance spectroscopy (MRS)dataand positron emission tomography (PET)images with aprototype MR-compatible,small animal PET imager. Journal of Magnetic Resonance Imaging . 2007
  • 6Schenck JF.The role of magnetic susceptibility in magneticresonance imaging:MRI magnetic compatibility of the first andsecond kinds. Medical Physics . 1996
  • 7Pichler BJ,Judenhofer MS,Catana C,et al.Performance test ofan LSO-APD detector in a 7-T MRI scanner for simultaneousPET/MRI. The Journal of Nuclear Medicine . 2006
  • 8Lucas AJ,Hawkes RC,Ansorge RE,et al.Development of acombined micro-PET-MR system. IEEE Nucl Sci SympConf Rec . 2006
  • 9Shao Y,Cherry SR,Farahani K,et a1.SimultaneousPET and MR imaging. Physics in Medicine and Biology . 1997
  • 10Cherry SR,Shao Y,Siverman RW,et al.Development of a PET detector system compatible with MRI NMR system. IEEE Transactions on Nuclear Science . 1997

同被引文献6