摘要
采用中红外光谱技术对牛奶中掺杂尿素目标物进行检测。配置含有尿素浓度范围为1~18 g.L-1之间18个牛奶样品,分别研究了纯牛奶和掺杂尿素牛奶的红外光谱特性,并进行了对比分析。利用尿素1 562 cm-1处酰胺Ⅲ带C O伸缩振动吸收峰面积A1 562与1 464 cm-1处C—N伸缩振动吸收峰面积A1 464的比值A1 562/A1 464对牛奶中尿素浓度进行线性拟合,研究结果表明A1 562/A1 464与牛奶中含有尿素浓度具有一定的线性关系,其相关系数达到0.96以上。该研究对提高乳制品的质量,保护消费者利益具有重要的社会意义和应用前景。
In the present study, a technique of mid infrared spectroscopy for detection of urea in milk was put forward. Eighteen adulterated milk samples with added different content of urea (1~18 g · L^-1) were prepared. The mid-infrared spectra of these milk samples were measured. The infrared characteristics of pure milk and adulterated milk were studied, and analysis and com- parisons of the differences were carried out. The absorption peak area (A1 s62) of 1 562 cm^-1 , which was assigned to the C--N stretching vibration for urea, and the absorption peak area (A1 464) of 1 464 cm 1, which was assigned to the C=O stretching vibration for amide Ⅲ, were calculated by origin. Linear fitting of relation was made between A1462/A1 464 and urea concentra- tion in milk. The results show that the A1462/A1464 is linear with urea concentration in milk, with a regression coefficient of 0.96. The study is important to improving quality of dairy products and protecting the benefit of consumers, and takes on crucial social significance and application prospect.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
2011年第9期2383-2385,共3页
Spectroscopy and Spectral Analysis
基金
国家自然科学基金项目(60938002
309009275)
高等学校博士学科点专项科研基金项目(20090032120064)资助
关键词
中红外光谱
牛奶
尿素
掺杂
Mid-infrared spectroscopy
Milk
Urea
Adulteration