摘要 水分是导致沿面爬电的重要原因之一,为研究高水分质量分数绝缘纸板的沿面爬电特性,分析了实际变压器中绝缘纸板可能达到的高水分质量分数值,建立了绝缘纸板沿面爬电特性试验装置,制备了相应高水分质量分数的绝缘纸板,对其沿面爬电过程进行了观测。研究结果表明:油中水分质量分数在30×10-6时,变压器中绝缘纸板的局部水分质量分数有可能达到7%以上,其沿面爬电平均起始场强仅为约0.3 kV/cm,远低于实际变压器中的许用场强;沿面爬电首先在高低压电极处的卡槽连接处起始,放电量可达20000 pC,呈间歇性发展,会在绝缘纸板表面造成碳痕与"白斑"等损伤;沿面爬电的产气率较大,产生气体中H2、C2H2和CO的体积分数较高。 High moisture in pressboard may be a predominant factor causing creepage discharge failure in power transformer. To research the creepage discharge performance of high moisture pressboard, possible high moisture in pressboard of power transformer was analyzed according to Oommen paper-oil moisture equilibrium curves, and a creepage discharge simulation and test setup and measurement system were established, which were consisted of creepage discharge model, test tank, Zhongfen 2000 A gas-phase chromatographic instrument, and DST-4 partial discharge detector. Moreover, a creepage discharge model was constructed by 25 cm-long pressboard between plate electrode and ball electrode. When the moisture of pressboard reached 7% in creepage discharge process, the appar- ent discharge magnitude and dissolved gases in oil were measured. The results show that moisture of part pressboard may reach to 7% when oil) moisture is 30× 10^-6, and the inception electric field strength of ereepage diseharge is on- ly about 0.3 kV/cm which is much lower than available electric field strength of transformer; creepage discharge ap- pears at small oil gap in high voltage and ground electrode firstiy and its apparent discharge magnitude is about 20000 pC; creepage discharge is intermittent and even stops at some time; bright are and lots of bubbles can be ob- served; dissolved gases contents generated by creepage discharge are very high, especially H2, CO and Cz Hz.
出处 《高电压技术》 EI CAS CSCD 北大核心 2011年第8期1924-1929,共6页 High Voltage Engineering
基金 国家重点基金研究发展计划(973计划)(2009CB724508)~~
关键词 变压器 纸板 水分质量分数 爬电 溶解气体 白斑 power transformer pressboard moisture ereepage dissolved gases white mark
  • 相关文献

参考文献24

二级参考文献20

  • 1顾洁.基于物元模型的电力系统中长期负荷预测[J].电力系统及其自动化学报,2004,16(6):68-71. 被引量:10
  • 2胡超凡,陈刚,赵玉柱.2004年国家电网安全运行情况分析[J].中国电力,2005,38(5):9-12. 被引量:22
  • 3Oommen T V 赵宗平(译).用于变压器绝缘干燥工艺的含平衡曲线图[J].变压器,1985,22(4):26-29.
  • 4莫瑟H P 朱英浩(译).绝缘纸板[M].沈阳:辽宁科学技术出版社,1997..
  • 5.GB/T15164-1994.油浸式电力变压器负载导则[S].,1994..
  • 6郭永基.一种基于绝缘纸粘度测定的变压器寿命评估方法[A]..北京:电工产品可靠性学术年会论文集[C].,1997..
  • 7莫瑟H P 达欣登V 朱英浩 赵育文译.变压器绝缘纸板[M].沈阳:辽宁科学技术出版社,1997..
  • 8DL755-2001.电力系统安全稳定导则[S].[S].,..
  • 9牛东晓 曹树华 赵磊.电力系统负荷预测理论与应用[M].北京:中国电力出版社,1998..
  • 10DL558-94.电业生产事故调查规程[S].[S].,..

共引文献344

同被引文献96

引证文献11

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部