摘要
通过对湖北城市配网供电能力相关数据研究分析,并结合日本东京电力公司配电网技术,提出10kV线路合理装接容量以及配变合理装接户数的技术建议。
Through the analysis on relevant data of urban distribution system supply capacity in Hubei province with a reference to distribution system technology in Tokyo electric power enterprise,Japan,the technical advices are presented for the reasonable accessing capacity in 10kV transmission line and the reasonable accessing number of loads on distributing transformer.
出处
《湖北电力》
2011年第4期39-41,共3页
Hubei Electric Power
关键词
配网
供电能力
线路装接容量
distribution system
supply capacity
accessing capacity in transmission line