期刊文献+

零件尺寸图像检测数据处理与高精度检测方法 被引量:7

Methods of Data Processing and High Accurate Detection for Image Detection of Part Sizes
下载PDF
导出
摘要 针对机器视觉在轴类零件尺寸检测中的应用,提出了一种利用工业中常用的标准件同时完成视觉检测系统的图像畸变校正与系统标定的方法,有效的提高了检测精度,简化了传统系统标定的繁琐过程。该方法通过分析图像检测中误差形成的主要来源,建立了误差方程的正规方程式,在求解正规式系数的同时完成对检测系统的校正与标定。不但操作简单,且具有较高的检测精度。经实验证明,在检测分辨率为3450DPI的情况下,检测精度可达到4μm,完全适用于轴类零件的高精度检测。 For the use of Machine Vision in shaft size detection, this paper propose a method which completes the image distortion correction and system calibration by using commonly used industry standard parts. This method effectively improves the detection accuracy, simplifies the tedious process of calibration of conventional systems. By analyzing the main causes of error in image detection, the formal equation from error equation is established. Image distortion is corrected and calibrated at the same time. The coefficient of normal-type is calculated. This method is not only simple, but also effective to improve the accuracy of the image detection. The experiment proves that detection accuracy can reach 4μm at the resolution of 3450DPI, completely applicable to high-precision detection of shaft.
出处 《计算机系统应用》 2011年第9期248-251,共4页 Computer Systems & Applications
基金 教育部广东省产学研结合项目(2010B090400382)
关键词 视觉检测 尺寸检测 畸变校正 标定 标准件 machine visual inspection size detection distortion correction calibration standard part
  • 相关文献

参考文献4

二级参考文献22

共引文献74

同被引文献50

  • 1杨顺辽.基于Hough变换提取直线的改进方法研究[J].电脑与信息技术,2006,14(5):29-31. 被引量:24
  • 2陈盖凯.基于Hough变换的直线检测[J].西安航空技术高等专科学校学报,2007,25(3):34-36. 被引量:16
  • 3孙航,耿爱辉,张海波,等.基于线阵CCD的精密测角系统[J].嵌入式系统应用,2009,29:61-62.
  • 4HORAUD R, MOHR R, LORECKI B. Linear-camer- a calibration [C] /// Proceedings of the 1992 IEEE In ternational Conference on Robotics and Automation. Piscataway, NJ, USA: IEEE, 1992:1539-1544.
  • 5斯蒂格,尤里奇,威德曼.机器视觉算法与应用:双语版[M].杨少荣,译.北京:清华大学出版社,2008:261-267.
  • 6WANG Jianhua, SHI Fanhuai, ZHANG Jing, et al. A new calibration model of camera lens distortion [J]. Pattern Recognition, 2007, 41: 607-615.
  • 7DEVERNAY F, FAUGERAS O. Straight lines have to be straight [J].Machine Vision and Applications, 2001, 13: 14-24.
  • 8WENG J,COHEN P, HERNIOU M. Camera calibra with distortion models and accuracy evaluation IEEE Transactions on Pattern Analysis and Ma- Intelligence, 1992, 14(10): 965-980.
  • 9AHMED M, FARAG A. Nonmetric calibration of camera lens distortion: differential methods and robust estimation [J]. IEEE Transactions on Image Process- ing, 2005, 14(8): 1215-1230.
  • 10吴国栋,韩冰,何煦.精密测角法的线阵CCD相机几何参数实验室标定方法[J].光学精密工程,2007,15(10):1628-1632. 被引量:51

引证文献7

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部