摘要 运用碱性过硫酸钾-紫外分光光度法对总氮的标准样品及实际样品进行研究分析,通过全国多家实验室的大量监测数据,得出了当前常用的精密度及准确度方面质量控制指标的建议值。研究表明:标准样品在0.5~3.5mg/L浓度范围内,相对标准偏差RSD≤5.0%;室间相对标准偏差RSD′≤10%;相对误差RE≤±10%;实际样品在0.07~10mg/L浓度范围内时,相对偏差RD≤10.0%;加标回收率范围为90%~110%。 The standard sample and the real samples of total nitrogen were analyzed with Alkaline potassium persulfate digestion-UV spectrophotometry.Based on a large number of monitoring data from many laboratories of the country,common recommended values of precision and accuracy for quality control were obtained.The results showed that when the concentration of standard sample was in the range of 0.5~3.5mg/L,the relative standard deviation,the inter-laboratory relative standard deviation and the relative error were RSD≤5.0%,RSD′≤10% and RE≤±10% respectively.When the concentration of real samples ranged in 0.07~10 mg/L we had RD≤10.0% and the spike recoveries ranged in 90%~110%.
出处 《四川环境》 2011年第4期21-24,共4页 Sichuan Environment
基金 环保公益性行业科研专项项目(200809140)
关键词 总氮 碱性过硫酸钾-紫外分光光度法 质量控制指标 Total nitrogen alkaline potassium persulfate digestion-UV spectrophotometry quality control index
  • 相关文献

参考文献3

  • 1CB/T11894-1989,水质总氮的测定碱性过硫酸钾-紫外分光光度法[S].
  • 2国家环境保护总局水和废水监测分析方法编委会.水和废水监测分析方法(第四版)[M].北京:中国环境科学出版社,2002.32-37.
  • 3中国环境监测总站《环境水质监测质量保证手册》编写组.环境水质监测质量保证手册(第二版)[M].北京:化学工业出版社,1994..