期刊文献+

锅炉一次风机失速现象分析讨论 被引量:6

ANALYSIS OF ONE STALL PHENOMENON OCCURRED ON PRIMARY AIR FAN OF BOIELR
下载PDF
导出
摘要 针对国投钦州电厂一次风机在磨煤机起停过程中出现的失速现象进行了详细的分析,找出了一次风机失速原因,并提出了解决方案。本例一次风机失速原因为停1台磨煤机时,每台一次风机的平均流量小于其失速流量,因此必有1台一次风机失速。 Directing against the stall phenomenon occurred on the primary air fan during start- up and shutdown process of the coal pulverizer in Guotou Qinzhou Power Generation Co Ltd, analysis has been carried out in detail,the causes leading to stall of the primany air fan being found, and the resol- ving scheme being put forward. The cause resulting in said stall of the primany air fan was due to the average flow rate of each primary air fan being smaller than its flow rate during shutdown of one coal pulverizer,hence,it is inevitable to cause ~t^ll cff nn,~ n^i,-. ~ ~..
出处 《热力发电》 CAS 北大核心 2011年第8期68-70,共3页 Thermal Power Generation
关键词 电站风机 一次风机 失速 磨煤机 节能降耗 air fan in power plant energy - saving and consumption - reducing ~ energy - saving scheme
  • 相关文献

参考文献2

  • 1AST-1750/1250型动叶可调式轴流风机使用说明[Z].
  • 2国投钦州发电有限公司2号机组一次风机失速诊断试验报告[R].西安:西安热工研究院有限公司,2008.

同被引文献38

引证文献6

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;