通过对30个免烧非蒸压高掺量粉煤灰砖砌体的抗剪试验,分析了粉煤灰砖砌体的受剪承载力特点及其变化规律,给出了粉煤灰砌体抗剪强度的建议公式。计算结果表明,免烧结粉煤灰砖砌体的抗剪强度高于普通粘土砖设计值,设计值的建议公式为fv=0.37fv,m。本试验的研究,可为我国墙体材料标准的编制和修订提供依据。
Based on the shear tests of 30 brick masonry made by non-steam high percentage fly-ash,the paper discusses the developing feature of shear bearing capacity and provides equation of shearing strength of fly-ash brick masonry.The result show shearing strength of fly-ash brick masonry is higher than normal brick masonry,suggested equation is fv=0.37fv,m,which can provide reference for compile and revise the standard of wall materials in China.
出处
《四川建筑科学研究》
北大核心
2011年第4期213-215,共3页
Sichuan Building Science
关键词
免烧结
高掺量
粉煤灰砖
抗剪强度
non-sintered
high percentage
fly-ash brick masonry
shearing strength