对于110kV及以上变电站通信设备的-48V直流电源应该采用“AC-DC独立通信电源”,还是采用“操作电源+DC-DC一体化电源”是有争议的。针对这个问题进行了技术分析和比较,结论为:不推荐采用“操作电源+DC-DC的一体化电源”给变电站系统通信各设备供电,因为其职能层次、安全可靠性和电源质量均比不上“AC-DC独立通信电源”。
There is a controversy for the -48 V DC power supply to communication devices in substations of 110 kV or above: whether "AC-DC independent power supply" or "Operating power supply + DC-DC integration power supply" should be adopted. Aiming at the issue, this article analyzes the two kinds of power supply and makes comparison between them, resulting in a conclusion that "Operating power supply + DC-DC integration power supply" is not recommended for the power supply to the system communication devices in the substations as its flmctional level, reliability and power source quality are worse than that of "AC-DC independent power supply".
出处
《南方电网技术》
2011年第A01期12-15,共4页
Southern Power System Technology
关键词
操作电源
AC-DC电源
DC-DC电源
一体化电源
后备电池
operation power source
AC-DC power source
DC-DC power source
integrated power source