期刊文献+

不同方位探测对光声成像的影响

Influence of Differential Detected-azimuth on Photoacoustic Imaging
下载PDF
导出
摘要 为了研究在不同方位探测光声信号对光声层析成像的影响,采用了数值仿真计算,得出了在有限角度扫描的情况下,吸收体分布与探测方向呈45度夹角时,成像效果较好;在条件允许的情况下,采用全方位探测扫描,其成像效果最好。该研究结果对光声成像扫描轨迹的设计、成像效果评估具有较好的参考价值。 In order to study the influence from different detected-azimuth on photoacoustic imaging, numerical calcula- tion is carried out. The results indicated that the good quality of photoacoustic imaging can be obtained when the angle between absorbers and detected direction is 45° for a limited-view scanning, and better quality of photoacoustic imaging can also be obtained in full-view scanning subject to the respective conditions. These are helpful for the choice of scanning radius and the evaluation of reconstructed images.
出处 《激光生物学报》 CAS CSCD 2011年第4期434-437,共4页 Acta Laser Biology Sinica
基金 陕西省科技厅基础研究项目(2011JM1016) 陕西省教育厅基础研究项目(2010JK0930)
关键词 医用光学与生物技术 光声成像 不同探测方位 medical optics and biotechnology photoacousitc imaging differential detected-azimuth