摘要
本文介绍了在对原谱仪的部分非真空接口、快门等结构进行改进的基础上,对掠入射消象差光栅谱仪进行全面调试和相谱的方法,并得出了结果。
This paper describes the comprehensive adjustment and spectrum photographing method of the stigmatic grazing incidence spectrometer in connection with the improvement, in part, of the non-vaccum interface and the shutter etc. of the prime spectral instrument, and the results achieved is also given.
出处
《光学仪器》
1989年第3期39-43,共5页
Optical Instruments