摘要 采用金纳米粒子修饰铂微电极(Au-NPs/Pt)为"探针",研究其在微波-伏安法协同体系下检测Pb(Ⅱ)的电化学性质.微波辐射的"自聚焦"作用导致微电极/电解质扩散层形成"热点效应"、温度梯度和对流传质.采用单电子氧化还原Fe(CN)64-/3-/K2SO4(pH 3)体系对电极/电解质界面温度进行校正.研究结果发现,低功率微波对Au-NPs/Pt微电极的电化学性质影响较为明显.采用微波-伏安法检测Pb(II)的溶出电流极大增强,比传统方法增大近10倍.常规条件下易于阻塞电极的表面活性剂在微波-伏安协同体系中对Pb(Ⅱ)峰电流的影响也大大减小. Gold nanoparticles-modified platinum(Au-NPs/Pt) microelectrode is used as a "probe",and applied to detect Pb(II) in the presence of microwave irradiated-voltammetry synergetic system.Self-focusing of the microwave radiation creates a "hot spot" at the electrode/electrolyte interface within the diffusion layer of the electrode with an inverted thermal gradient and convective flow.The temperature at the electrode/solution interface is calibrated with reversible one electron redox system in aqueous K2SO4 solution(pH 3).The results indicate that the electrochemical performance at the Au-NPs/Pt microelectrode is significantly affected under the low microwave power.The Pb(II) stripping current at the(Au-NPs/Pt) microelectrode is shown to be strongly enhanced by microwave irradiated-voltammetry,which triggers approximately 10-times Pb(II) current response compared to those expected values in conventional conditions.The effect of surfactant,which blocks the electrochemical Pb(II) signal under conventional conditions,is remarkably reduced under the microwave radiation of voltammetry process.
出处 《化学学报》 SCIE CAS CSCD 北大核心 2011年第16期1929-1935,共7页 Acta Chimica Sinica
基金 国家自然科学基金青年基金(No.21005014) 东华大学校基金(No.113100044029)资助项目
关键词 微波辐射 伏安法 热点效应 microwave irradiation voltammetry "hot spot" effect lead
  • 相关文献

参考文献27

  • 1Thomas, Jr. J. R. Catal. Lett. 1997, 49, 137.
  • 2Raghuveer, M. S.; Agrawal, S.; Bishop, N.; Ramanath, G. Chem. Mater. 2006, 18, 1390.
  • 3Deilmann, M.; Theiss, S.; Awakowicz, P. Surf Coat. Technol. 2008, 202, 1911.
  • 4Tavares, O.; Morais, S.; Pafga, P.; Deleme-Matos, C. Anal. Bioanal. Chem. 2005, 382, 477.
  • 5Compton, R. G.; Coles, B. A.;Marken, F. Chem. Commun 1998,23,2595.
  • 6Tsai, Y.-C.; Coles, B. A.; Compton, R. G.;Marken, F. J Am. Chem. Soc. 2002,124,9784.
  • 7Sur, U. K.; Marken, F.; Compton, R. G.; Coles, B. A. New J. Chem. 2004, 28, 1544.
  • 8Marken, F.; Tsai, Y.-C.; Coles, B. A.; Matthews, S. L.; Compton, R. G. New J. Chem. 2000, 24, 653.
  • 9Ghanem, M. A.; Compton, R. G.; Coles, B. A.; Canals, A.; Marken, F. Analyst 2005, 130, 1425.
  • 10Marken, F.; Matthews, S. L.; Copmton, R. G.; Coles, B. A. Electroanalysis 2000, 12, 267.

同被引文献14

  • 1吴虓飞,张育辉.酚类环境雌激素对生殖及其发育机制的研究进展[J].毒理学杂志,2005,19(1):55-57. 被引量:3
  • 2Cai Yaqi, Jiang Guibin, Liu Jingfu, et al. Multi- walled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol A, 4-n- nonylphenol and 4-tert-octylphenol [J]. Anal Chem, 2003, 75(10): 2517-2521.
  • 3Iijima S. Helical microtubutes of graphitic carbon[J]. Nature, 1991, 354: 56-58.
  • 4Alexeyeva N, Laaksonen T, Kontturi K, et al. Oxygen reduction on gold nanopartical/multi-walled carbon nanotubes modified glassy carbon electrodes in acid solution[J]. Electrochem Commun, 2006, 8: 1475- 1480.
  • 5Tedim J, Goncalves F, Pereira M F R, et al. Prepa- ration and characterization of poly ~Ni(salen)(crown receptor) ]/multi-walled carbon nanotube composite films [J]. ElectrochimActa, 2008, 53 : 6722 - 6731.
  • 6Luczak T. Preparation and characterization of the do- pamine film electrochemically deposited on a gold template and its application for dopamine sensing in aqueous solution [J]. Electrochim Acta, 2008, 53 : 5725 - 5731.
  • 7Laviron E. Adsorption, autoinhibition and autocataly- sis in polarography and in linear potential sweep vol- tammetry[J]. J Electroanal Chem, 1974, 52:355 - 393.
  • 8Bard A J, Faulkner L R. Electrochemical Methods: Fundamentals and Applications [ M ]. 2nd ed. New York: JohnWiley and Sons Inc, 2001:97 - 102.
  • 9Pan Mingfei, Fang Guozhen, Duan Zhenjuan, et al. Electrochemical sensor using methimazole imprinted polymer sensitized with MWCNTs and Salen-Co(III) as recognition element [J]. Biosens Bioelectron, 2012, 31: 11-16.
  • 10吕刚,王利兵,刘军,李淑芬.包装材料中的酚类环境雌激素的测定-固相微萃取/气相色谱质谱法[J].分析试验室,2008,27(9):73-75. 被引量:35

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部