期刊文献+

吹脱法处理化肥厂氨氮废水的研究 被引量:2

THE STUDY OF NITROGEN REMOVAL BY AMMONIA STRIPPING
下载PDF
导出
摘要 在实验的基础上选用塔滤吹脱——接触氧化工艺处理化肥厂氨氨废水,使出水浓度低于10mg/l;井提出实验室最佳运行参数及工艺流程;采用空气预热的方法较好地解决了严寒地区结冰期吹脱塔运行的问题,通过控制 pH 值和选用塑料条板填料克服了塔内结垢的弊端。 The combined method of ammonia stripping and contact oxidation was yield in treatment of wastewater from fertilizer industry.By experim- ent,the optinum operating parameters were acquired,the best flow chart was selected,and ammonianitrogen was less than 10 mg/1 in outlet wastew- ater.Concerning the temperature of inlet wastewater,the better purificat- ion result was achieved in freeze season by preheating inlet air.with con- troling PH value and selecting plastic filling filler,the lath of CaCo_3 was overcome in pilot plant.
出处 《新疆环境保护》 1990年第1期41-50,共10页 Environmental Protection of Xinjiang
关键词 氨氮废水 吹脱法 化肥厂 废水处理 ammonia striping ratio of air to water aipreheating tower filter
  • 相关文献

同被引文献13

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部