摘要
在SO2与H2S共存下,利用便携式气相色谱法测定了固定污染源排气中硫化氢含量。方法简便快速,准确度和精密度较高,受干扰物质二氧化硫的影响小,测定结果完全满足复杂成分烟气中硫化氢的测定要求。
Under the coexistence of SO2 and H2S,the concentration of hydrogen sulfide exhausted from stationary pollution source was measured by Portable-Gas-Chromatogram(PGC) method.The Portable-Gas-Chromatogram(PGC) method is simple and rapid,and the measured results can completely meet the requirement of H2S among complex components.
出处
《中国环境监测》
CAS
CSCD
北大核心
2011年第4期60-62,共3页
Environmental Monitoring in China
基金
环境保护部科技基金(锶盐工业污染物排放标准
2008-494.14)
关键词
便携式气相色谱
固定污染源
硫化氢
Portable GC
Stationary pollution source
Hydrogen sulfide