摘要 介绍了马钢彩涂生产线预处理段设备和工艺状况,描述了关于预处理段补水溢流情况,通过实验和数据分析,将湿段补水量降低30%,使脱脂剂溢流量降低20%,在达到好的清洗效果的同时,降低了脱脂剂的消耗,从而做到了降本增效。 This article briefly describes the pretreatment section of masteel coil coating line's equipments and technology,and describes the situation on water overflowing of pretreatment,then finished experiment and data analysis,wet wection through a reasonable lowering of water 30%,degreaser spill flow 20%,reaching good cleaning results while reducing the consumption of cleaning agent,thereby reducing costs and increasing efficiency.
作者 汪林
出处 《安徽冶金科技职业学院学报》 2011年第3期61-63,共3页 Journal of Anhui Vocational College of Metallurgy and Technology
关键词 预处理 脱脂剂 补水 溢流 pretreaemtne cleaning agent filling water overflow