期刊文献+

2种空冷风机桥架的振动特性分析与对比 被引量:5

Vibration Characteristics Analysis and Contrast of Bridge Structures between Two ACC Fans
原文传递
导出
摘要 风机桥架的振动特性取决于其结构形式。文章利用有限元分析软件ANSYS对2种不同结构形式的空冷风机桥架进行比较。通过模态分析对比2种风机桥架的刚度和振动频带,并采用谐响应方法对比2种风机桥架在正常运行不平衡力、叶片断裂时不平衡力以及电动机正常运行不平衡力等激振载荷作用下的频率响应特性。分析结果表明,通过优化风机桥架的结构形式可以改善其振动特性。 Vibration characteristics of fan bridge are determined by the structure. Based on ANSYS software, the stiffness and vibration bands of two types of ACC fan bridge structures are analyzed by modal analysis. Furthermore, the frequency response curves under three different vibration loads are calculated separately by harmonic response method, which of the two fan bridges are contrasted. It is demonstrated that the vibration characteristics of fan bridge are improved by structural optimization.
出处 《电力建设》 2011年第9期6-10,共5页 Electric Power Construction
基金 国家科技支撑计划项目(2009BAA16B00) 黑龙江省杰出青年科学基金资助项目(JC200912)
关键词 直接空冷 风机桥架 模态分析 谐响应分析 振动特性 direct air cooling fan bridge modal analysis harmonic response analysis vibration characteristic
  • 相关文献

参考文献5

二级参考文献27

  • 1李红星,赵春莲,师小虎.空冷风机桥架谐响应计算分析[J].武汉大学学报(工学版),2008,41(S1):104-107. 被引量:13
  • 2吴高峰,杜健民,陈兴冲.ANSYS软件在高层建筑地震反应分析中的应用[J].兰州交通大学学报,2001,22(6):53-56. 被引量:5
  • 3李国强,方明霁,刘宜靖,陆烨.钢结构住宅体系加气混凝土外墙板抗震性能试验研究[J].土木工程学报,2005,38(10):27-31. 被引量:54
  • 4姚泽良 白国良 李晓文 等(YaoZe-liang BaiGuo-liang LiXiao-wen etal).1000MW空冷凝汽器支架结构局部沉降有限元分析(Finite element analysis on local settlement of 1000MW air cooled support structure).哈尔滨工业大学学报,2007,39(1):587-590.
  • 5Yao Ze-liang, Bai Guo-liang. Vibration analysis on 1 000 MW air cooled support structure under excitation of large-diameter fans: Proceedings of the tenth international symposiurn on structural engineering for yong experts [ C ]. 2008 : 1 605-1 610.
  • 6Bartz J H. Dry cooling of power plants-amature technology [J]. Power Engineering, 1998, 10( 1 ) : 23-28.
  • 7Knirach H. Design and construction of large direct dry cooled units for thermal power plants[ J]. ASME 90-JPGC/Pwr-26, 1990,15(4) : 66-70.
  • 8傅恒箐(Fu Heng-qing).建筑结构试验(Building Structure Experiments)[M].北京:冶金工业出版社(Beijing:Metallurgical Industry Press),1992.
  • 9白国良 李红星 李晓文 等(BaiGuo-liang LiHong-xing LiXiao-wen etal).厂房动力特性测试及加固效果评估(Experiment and evaluation on dynamic behaviors of factory buildings).世界地震工程,2004,12(6):22-25.
  • 10张崇文 曾思庄(ZhangCong-wen ZengSi-zhuang).框架式结构自振特性基本规律的研究(Dynamic analysis on frame structural).建筑结构,1989,10(6):4-9.

共引文献20

同被引文献25

引证文献5

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部