超临界水氧化处理焦化废水实验研究 被引量:2

Study on the treatment of coking wastewater by supercritical water oxidation technology
下载PDF
导出
摘要 采用超临界水氧化法对焦化废水进行处理研究,探讨了反应温度、时间和压力等因素对废水处理效果的影响。实验结果表明,在氧气过量2倍~3倍的条件下,实验系统的压力为28 MPa,反应时间为60 s,反应温度为580℃,焦化废水的CODCr去除率可达99.5%以上。 The coking wastewater was treated by supercritical water oxidation process.The effects of residence time,reaction pressure on the results of the treatment were investigated and the process conditions of supercritical water oxidation process were optimized.The results showed that when reaction pressure was 28 MPa,residence time was 60 s,reaction temperature was 580 ℃,and oxygen was exceeded 2 to 3 times,the removal rate of CODCr of the wastewater could be over 99.5%.
作者 胡树枝
出处 《山西化工》 2011年第4期65-67,共3页 Shanxi Chemical Industry
关键词 超临界水氧化 焦化废水 废水处理 去除率 supercritical water oxidation coking wastewater wasterwater treatment removal rate
  • 相关文献

参考文献3

二级参考文献23

共引文献51

同被引文献25

  • 1左蓓璘,方涛,朱立勋,杜建峰,张维海.超临界水氧化技术中有关设备腐蚀问题的研究进展[J].现代化工,2011,31(S2):33-35. 被引量:6
  • 2王亮,王树众,张钦明,赵威,林宗虎.超临界水氧化处理含油废水的实验研究[J].环境污染与防治,2005,27(7):546-549. 被引量:34
  • 3Takahashi F,Sun,ZR,Fukushi K,et al.Catalytic oxidation of aceticacid over sodium titanate synthesized hydrothermally in supercritical wa-ter[ J].The Journal of Supercritical Fluids,2012,61 ; 126-133.
  • 4Sogtit 00,Akgun M.Treatment of dyehouse waste-water by supercriti-cal water oxidation:a case study [ J].Journal of Chemical Technologyand Biotechnology,2010,85 (5):640-647.
  • 5SfDgut 00,AkgUn M.Removal of Cl Basic Blue 41 from aqueous solutionby supercritical water oxidation in continuous-flow reactor[ J].Journalof Industrial and Engineering Chemistry,2009,15(6):803-808.
  • 6Cui BC,Cui FY,Jing GL,et al.Oxidation of oily sludge in supercriticalwater[J].Journal of hazardous materials,2009,165(1):511-517.
  • 7Shin YH,Shin NC,Veriansyah B,et al.Supercritical water oxidation ofwastewater from acrylonitrile manufacturing plant [ J].Journal of haz-ardous materials,2009,163(2):1142-1147.
  • 8Du X,Zhang R,Gan,ZX,et al.Treatment of high strength cokingwastewater by supercritical water oxidation[ J].Fuel,2013,104:77-82.
  • 9Feng D, Yu Z, Chen Y, et al. Novel single stripper with side-draw to remove ammonia and sour gas simultaneously for coal-gasification wastewater treatment and the industrial implementation [J]. Industrial & Engineering Chemistry Research,2009,48 (12): 5816-5823.
  • 10Wang Y Z, Wang S Z, Guo Y, et al. Oxidative degradation of Lurgi coal-gasification wastewater with Mn203, Co203 and CuO catalysts in supercritical water [J].Industrial & Engineering Chemistry Research,2013,51(51): 16573-16579.

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部