期刊文献+

生物传感器BOD快速测定仪电气控制系统 被引量:1

Electrical control system of BOD rapid determination instrument using biosensor
下载PDF
导出
摘要 生物需氧量(BOD)是一种表征水体有机污染程度的综合指标,广泛用于水体检测和污水处理厂的运行控制。概述了生物传感器BOD快速测定仪电气控制系统的工作原理,详细介绍了该仪器的硬件配置和软件设计,其用户界面设计为人机友好的视窗模式,从而实现自动检测实时显示等功能,能够满足水体有机污染快速准确检测的要求,对于我国水质评价、合理利用水资源及水处理效率的提高具有重要意义。 Characterization of biochemical oxygen demand (BOD)is a comprehensive index which shows the degree of organic pollution of water. The index is widely used in operation control of water test and wastewater treatment p^tant. The operating principle of electrical control system of BOD rapid determination instrument using biosensor is outlined. The purpose and significance of the system is introduced briefly. Hardware configuration and software design of the instrument are detailed. User-friendly man-machine interface is designed for the window mode in order to achieve the function of automatic detection of real-time display to meet the requirements of quick and accurate test of organic pollution. It' s important for the evaluation of water quality, rational use of water resources and water efficiency.
出处 《传感器与微系统》 CSCD 北大核心 2011年第9期88-90,94,共4页 Transducer and Microsystem Technologies
关键词 生物需氧量 DS18B20温度传感器 单片机 程序模块 人机界面 biochemical oxygen demand (BOD) temperature sensor DS18B20 MCU program module mancomputer interface
  • 相关文献

参考文献7

二级参考文献75

共引文献29

同被引文献15

  • 1卓明,冯裕钊,陈勇.软测量技术在污水处理过程中的应用[J].中国给水排水,2005,21(11):34-36. 被引量:4
  • 2S.G. Won,C.S. Ra.Biological nitrogen removal with a real-time control strategy using moving slope changes of pH(mV)- and ORP-time profiles[J].Water Research.2010(1)
  • 3Shaopo Wang,Jingjie Yu,Tianlan Wei,Yongzhi Chi,Liping Sun,Yongzhen Peng.Applying real-time control for achieving nitrogen removal via nitrite in a lab-scale CAST system[J].Environmental Technology.2012(10)
  • 4Lee, Eunhyoung,Han, Sanghoon,Kim, Hyunook.Development of Software Sensors for Determining Total Phosphorus and Total Nitrogen in Waters[J].International Journal of Environmental Research and Public Health.2013(1)
  • 5Jihyun Kwak,Bumju Khang,Eunhee Kim,Hyunook Kim,Mohammad A. Al-Ghouti.Estimation of Biochemical Oxygen Demand Based on Dissolved Organic Carbon, UV Absorption, and Fluorescence Measurements[J].Journal of Chemistry.2012
  • 6Shengbo Gu,Shuying Wang,Qing Yang,Pei Yang,Yongzhen Peng.Start up partial nitrification at low temperature with a real-time control strategy based on blower frequency and pH[J].Bioresource Technology.2011
  • 7Karube I,Matsunaga T,Mitsuda S,Suzuki S.Microbial electrode BOD sensors[].Biotechnology and Bioengineering.1977
  • 8Carstensen, Jacob,Harremo?s, Poul,Strube, Rune.Software sensors based on the grey-box modelling approach[].Water Science and Technology.1996
  • 9T.B. ?nnerth,M.K. Nielsen,Stamer C.Advanced computer controlbased on real and software sensors[].Water Science and Technology.1996
  • 10Ruano, M.V.,Ribes, J.,Seco, A.,Ferrer, J.Low cost-sensors as a real alternative to on-line nitrogen analysers in continuous systems[].Water Science and Technology.2009

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部