期刊文献+

矿井10MHz以下通信射频设备安全距离的研究 被引量:3

Safe distance for telecommunication radiofrequency transmitter with frequency below 10 MHz in underground mines
下载PDF
导出
摘要 建立了工作频率在10 MHz范围内的煤矿井下射频设备与雷管间安全距离的计算模型,将雷管脚线视为回路天线,得出了雷管脚线的内阻抗、回路线的互感系数以及外电感系数的计算公式,和流经回路线上的总电流公式,建立了射频设备与雷管间安全距离的计算公式。基于该模型,分析了射频发射设备的工作频率和雷管脚线面积变化对安全距离的影响。结果表明:煤矿井下射频设备与雷管之间的本安距离为3 m,即只要相距大于3 m,工作频率在10 MHz以下的射频设备,其辐射能量就不会对雷管构成安全隐患。 The computing model of safe distance between detonator and radiofrequency transmitter working at the frequency band below 10 MHz in coal mines was established.The detonator pin was considered as a loop antenna.Based on that,obtained the calculation formula of the internal resistance of detonator pin,the mutual and the external inductance of the loop line,and then the total current formula in the loop line was obtained,the calculation formula of safe distance between RF transmitter and detonator was deduced at the end.Two influences on safe distance in the model were analyzed,which were caused by the area of detonator pin and working frequency of RF transmitter.The results show that the safe distance between RF transmitter and detonator in underground mines is 3 meters.In other words,as long as the distance is over 3 meters,the radiation energy of transmitter with frequency below 10 MHz,will not be a threat to detonator.
出处 《煤炭学报》 EI CAS CSCD 北大核心 2011年第8期1417-1420,共4页 Journal of China Coal Society
基金 国家科技支撑计划资助项目(2006B4K03B00) 中央高校基本科研业务费资助项目(2009KJ03)
关键词 矿井 安全距离 工作频率 电雷管 雷管脚线面积 underground mine safe distance working frequency electric detonator detonator pin area
  • 相关文献

参考文献15

  • 1丁伯良.动物中毒病理学 [M].北京:中国农业出版社,1996.207.
  • 2Howson D P, Exeell P S, Butcher G H. Ignition of flammable gas mixtures by sparks from 2-MHz and 9-MHz sources[ J]. Radio and Electronic Engineer, 1981,51 (4) : 170 - 174.
  • 3James R A, Excell P S, Keller A Z. Probabilistic factors in radio-frequency ignition and detonation hazards analyses [J].Reliability Engineering, 1987,17 ( 2 ) : 139-153.
  • 4Hultberg B, Andersson A, Isaksson A. Alterations of thiolmetabolism in human cell lines induced by low amounts of copper,mercury or cadmium ions[J]. Toxicology, 1998, 126(3): 203- 212.
  • 5李锦荣.电火工品射频感度试验[J].兵工学报,1996,17(1):93-96. 被引量:4
  • 6王鹏,杜志明.桥丝式电火工品热点火理论[J].火工品,2007(4):26-30. 被引量:16
  • 7陈明华,张国安,陆瑞卿,邢立平.桥丝式电火工品射频感度试验研究[J].含能材料,2008,16(5):547-549. 被引量:4
  • 8封青梅,赵团,刘红利,李锦荣.电雷管射频感度试验的应用研究[J].国防技术基础,2007(9):22-24. 被引量:4
  • 9Secombes C J, Fletcher T C. The role of phagocytes in the protective mechanism of fish[J]. Annual Rev of Fish Diseases, 1992, 53- 72.
  • 10徐英含.环境病理学 [M].北京: 世界图书出版公司,1993.65-66.

二级参考文献19

共引文献31

同被引文献36

引证文献3

二级引证文献16