期刊文献+

电化区段信号电缆接地与烧损预防措施探讨 被引量:6

Discussion on Signal Cable Earthing and Measures of Preventing Burning in Electric Section
下载PDF
导出
摘要 近年来铁路先后发生多起信号电缆大面积烧损的事件,究其原因,主要是由于外部磁场的影响较大、电缆的接地方法不合理。对由外部磁场干扰而产生感应电流、电压的原理进行分析,并探讨电缆接地的方法,提出电缆接地的优化方案和防电缆烧损的措施,为工程实施和维护管理提出可行性建议。 Tens of signal cable burning events happened in recent years due to great influence of external magnetic field and unreasonable earthing methods of cables.This paper mainly analyzes the principles of generating induced current and voltage caused by interruption of external magnetic field,discusses the way of cable earthing,and puts forward the optimizing scheme and the measures of preventing cable burning as a feasible recommendation for project implementation and maintenance management.
作者 李长征
出处 《铁路通信信号工程技术》 2011年第4期67-69,共3页 Railway Signalling & Communication Engineering
关键词 信号电缆 防范 烧损 单端接地 双端接地 signal cable precaution burning out single end earthing double ends earthing
  • 相关文献

参考文献4

二级参考文献2

  • 1铁运[2006]6号关于印发《铁路信号设备雷电及电磁兼容综合防护实施指导意见》的通知[s].
  • 2GB50057--94(2000)建筑物防雷设计规范[S].

共引文献4

同被引文献31

  • 1张东胜,徐淑刚.关于区间贯通地线屡次被盗的思考[J].铁道通信信号,2007,43(3):31-32. 被引量:1
  • 2TB10621-2009,高速铁路设计规范[S].
  • 3中华人民共和国铁道部.铁运[2006]26号铁路信号设备雷电及电磁兼容综合防护实施指导意见[S].北京:2006.
  • 4TZ206-2007,客货共线铁路信号工程施工技术指南[s].
  • 5杨光虎.浅析综合贯通地线存在的问题及解决措施[J].铁路通信信号,2011(10):89-92.
  • 6TB 10009-2005.铁路电力牵引供电设计规范[S]..2005
  • 7Paul C R,McKnight J W.Prediction of crosstalk involving twisted pairs of wires-part I:A transmission-line model for twisted-wire pairs[J].IEEE Transactions on Electromagnetic Compatibility,1979,21(2):92-105.
  • 8Paul C R,McKnight J W.Prediction of crosstalk involving twisted pairs of wires-part II:A simplified low-frequency prediction model[J].IEEE Transactions on Electromagnetic Compatibility,1979,21(2):105-114.
  • 9Jullien C,Besnier P,Dunand M,et al.Advanced modeling of crosstalk between an unshielded twisted pair cable and an unshielded wire above a ground plane[J].IEEE Transactions on Electromagnetic Compatibility,2013,55(1):183-194.
  • 10Theethayi N,Mazloom Z,Thottappillil R.Technique for reducing transient voltages in multiconductor-shielded cables[J].IEEE Transactions on Electromagnetic Compatibility,2007,49(2):434-440.

引证文献6

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部