期刊文献+

微钛钉支抗负载前后周围液体中IL-8及sICAM-1水平的研究

The effects of orthodontic force on IL-8 and sICAM-1 level in the fluid around micro-implant anchorage
下载PDF
导出
摘要 目的:研究微钛钉支抗负载前后松动组与稳定组周围液体中细胞因子含量的变化,分析影响其稳定性的因素。方法:将20例接受微钛钉支抗治疗患者的40枚支抗种植钉按负载后的临床稳定性分为稳定组和松动组,取其负载前,负载1、2、3个月后周围液体,称重,用ELISA方法检测其中IL-8、sICAM-1含量的变化,SPSS17.0对所得数据进行分析。结果:微钛钉支抗负载后周围液体量、IL-8、sICAM-1表达量在种植支抗松动组明显升高(P<0.05);在负载相同的力后,随着负载时间的延长,支抗周围液体、IL-8及sICAM-1表达量在松动组明显高于稳定组(P<0.05)。结论:种植支抗松动组周围液体量及IL-8、sICAM-1水平的升高可能与其周围组织炎症的加剧有关,微钛钉支抗周围IL-8及sICAM-1的水平可较好的反应其稳定性。 Objective:To investigate the change of IL-8 and sICAM-1 in the fluid around micro-implant anchorage when applying orthodontic force,analyze the factors affecting implant anchorage's stability.Methods:The 40 implant anchorage were Divided into stable and unstable group by the situation after loading orthodontic force.The fluid was collected before and 1、2、3months after orthodontic force around implant anchorage.IL-8 and sICAM-1 levels were analyzed using ELISA,and data analysis was performed using the software package SPSS17.0.Results:Significant difference(P〈0.05) was shown in the indexes between the two groups.And also found in unstable implant anchorage during different loading time.Conclusion:The increase of the fluid around implant anchorage、IL-8 and sICAM-1 level in unstable implant anchorage group may be correlated with inflammation's intensification,the level of IL-8 and sICAM-1 can reflect the stability of implant anchorage effectively.
出处 《中国口腔种植学杂志》 2011年第2期90-93,共4页 Chinese Journal of Oral Implantology
基金 山西省科技攻关项目:编号2007031092-6
关键词 种植支抗 IL-8 可溶性细胞间粘附分子-1(sICAM-1) ELISA implant anchorage IL-8 soluble intercellular adhesion moleculer-1(sICAM-1) ELISA
  • 相关文献

参考文献19

  • 1Lee JS,Park HS,Kyung HM.Micro-implant anchor- age for Lingual treatment of a skeletal Class II mal- occlusion [J] .J Clin Otrhod,2001,35 (10) :643-647.
  • 2Buchter A,Wiechmann D,Koerdt S,etal.Load-related implant reaction of mini-implants used for or- thodontic anchorage.Clin Oral Implants Res 2005,16:473-479.
  • 3Cheng SJ,Tseng IY,Lee JJ,etal.A prospective study of the risk factors associated with failure of mini- implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 2004,19:100-106.
  • 4Fritz U,Ehmer A,Diedrich P.Clinical suitability of titanium microscrews for orthodontic anchorage-pre- liminary experiences.J Orofac Orthop 2004,65:410- 418.
  • 5Melsen B.Mini-implants? Where are we? J Clin Or- thod 2005,39:539-547.
  • 6嵇国平,于泉,沈刚.性别、年龄与微种植钉支抗稳定性的关系[J].上海口腔医学,2008,17(4):360-363. 被引量:27
  • 7孙新华,公柏娟,孙宏晨,白晶.微种植体支抗施力的时机与稳定性的关系[J].吉林大学学报(医学版),2008,34(1):61-64. 被引量:7
  • 8Kitagawa T,Tanimoto Y,Nemoto K,et al.Influence of cortical bone quality on stress distribution in bone around dental implant [ J] .Dent Mater J,2005,24 (2) :219-224.
  • 9Miyawaki S,Koyama I,Inoue M,etal.Factors associat- ed with the stability of titanium screws placed in the posterior region for orthodontic anchorage.Am J Or- thod Dentofacial Orthop 2003,124;373-378.
  • 10Heydenrijk K,Meijer HJ , van der Reijden WA , et al.Microbiota around root-form endosseous implants: A review of the literature [J] .Int J Oral Maxillofac Implants,2002,17 (6) :829-838.

二级参考文献94

共引文献70

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部