期刊文献+

人工全膝关节置换术中股骨假体旋转的研究进展 被引量:9

ADVANCEMENT OF ROTATIONAL ALIGNMENT OF FEMORAL PROSTHESIS IN TOTAL KNEE ARTHROPLASTY
原文传递
导出
摘要 目的综述人工全膝关节置换术(total knee arthroplasty,TKA)中股骨假体旋转评估研究进展,以减少假体旋转不良导致的术后并发症。方法查阅近年TKA术中股骨假体旋转定位参考轴线的基础及临床研究相关文献,并进行综合分析。结果股骨假体旋转不良可造成屈曲间隙不平衡和髌骨轨迹不良,术前应采用不同方法确定股骨假体旋转力线,并通过影像学技术及计算机导航技术进行手术前后评估,保证股骨假体的旋转位置良好,使术后膝关节功能获得最大程度的恢复。结论近年发展了多种手术技巧和新技术以确定股骨假体旋转力线,临床应用并获得较好效果。 Objective To introduce the concept and clinical applications of rotational alignment of the femoral prosthesis in total knee arthroplasty(TKA) so as to avoide the postoperative complications caused by rotational alignment.Methods The clinical and experimental research literature about rotational alignment of the femoral prosthesis in TKA was extensively reviewed and analyzed.Results Femoral prosthesis malrotation can lead to flexion gap unbalanced and undesirable patellar track.Rotation alignment of the femoral prosthesis is defined with radiological and computer assisted technique at pre-and post-operation,which can make the rotation alignment of the femoral prosthesis and the function of the knee favorable.Conclusion In recent years,many surgical skills and new techniques of defining the rotational alignment are developed,and good clinical results are achieved
出处 《中国修复重建外科杂志》 CAS CSCD 北大核心 2011年第9期1140-1144,共5页 Chinese Journal of Reparative and Reconstructive Surgery
关键词 人工全膝关节置换术 股骨假体旋转 骨关节炎 Total knee arthroplasty Femoral prosthesis rotation Osteoarthritis
  • 相关文献

参考文献35

  • 1Czurda T, Fennema P, Baumgartner M, et al. The association between component malalignment and post-operative pain following navigation-assisted total knee arthroplasty: results of a cohort/nested case-control study. Knee Surg Sports Traumatol Arthrosc, 2010, 18(7): 863-869.
  • 2Walde TA, Bussert J, Sehmisch S, et al. Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament ten- sion. Knee, 2010, 17(6): 381-386.
  • 3van der Linden-van der Zwaag HM, Valstar ER, van der Molen AI, et al. Transepicondylar axis accuracy in computer assisted knee surgery: a comparison of the CT-based measured axis versus the CAS-determined axis. Comput Aided Surg, 2008, 13(4): 200-206.
  • 4Classen T, Wegner A, Miiller RD, et al. Femoral component rotation and Laurin angle after total knee arthroplasty. Acta Orthop Belg, 2010, 76( 1): 69-73.
  • 5Abadie P, Galaud B, Michaut M, et al. Distal femur rotational align- ment and patellar subluxation: a CT scan in vivo assessment. Orthop Traumatol Surg Res, 2009, 95(4): 267-271.
  • 6Insall J, Ranawat CS, Scott WN, et al. Total condylar knee replacement: preliminary report. Clin Orthop Relat Res, 1976, (120): 149-154.
  • 7Heesterbeek PJ, Jacobs WC, Wymenga AB, et al. Effects of the balanced gap technique on femoral component rotation in TKA, Clin Orthop Relat Res, 2009, 467(4): 1015-1022.
  • 8Dennis DA, Komistek RD, Kim RH, et al. Gap balancing versus mea- sured resection technique for total knee arthroplasty. Clin Orthop Relat Res, 2010, 468(1): 102-107.
  • 9Berger RA, Rubash HE, Seel MJ, et al. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res, 1993, (286): 40-47.
  • 10Churchill DL, Incavo SJ,Johnson CC, et al. The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res, 1998, (356): 111-118.

二级参考文献6

共引文献64

同被引文献89

引证文献9

二级引证文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部