珠海发电厂循环水供水系统水力瞬变的控制

Control of hydraulic transient of the circulating water supply system in Zhuhai power station
下载PDF
导出
摘要 文章根据珠海发电厂循环水供水系统工程布置的特点,研究了事故断电条件下水力瞬变引起的液柱分离现象及其防止措施,提出了求解空气阀瞬变过程的新模型。计算研究表明,可以采用沿线布置空气阀防止瞬变液柱分离破坏。分析了现行凝汽器数学模型与水柱分离及再弥合判断条件存在安全裕度较大等问题。 According to the characteristics of the project layout of the circulating water supply system in Zhuhai Power Station,this paper analyzes the liquid-column separation phenomenon caused by hydraulic transient under the condistion of power off and it's preventive measures,puts forward the new model to solve the transient process of air valve.Calculation and study shows that air valve can be arranged along the line to prevent the separation and damage of transient liquid-column.This paper also analyzes the problem of larger safety margin of judging condition of the current condenser mathematical model separating from water column and re-bridge with it.
作者 杨扬
出处 《企业技术开发》 2011年第8期11-14,共4页 Technological Development of Enterprise
关键词 供水系统 液柱分离 水力瞬变 水锤 空气阀 调压井 water supply system liquid-column separation hydraulic transient water hammer air valve surge tank
  • 相关文献

参考文献3

  • 1[美]E.B.怀利,V.L.斯特里特著,清华大学流体传动与控制教研组译.瞬变流[M].北京:水利电力出版社,2002.
  • 2刘竹溪,刘光临.泵站水锤及其防护[M].北京:中国水利水电出版社,1998.
  • 3刘光临.江西省九江第三水厂水源泵站水锤分析及防护技术研究报告[R].九江:江西省九江第三水厂,2000.