期刊文献+

动脉血压波关键点检测的迭代方法

Iterative Detection of Key Points in Arterial Blood Pressure Wave
下载PDF
导出
摘要 提出一种检测动脉血压(ABP)波起始点位置和峰值位置的迭代算法。该方法应用斜坡和函数处理原始信号,以迭代的方法标识每个波动周期的起始位置和峰值位置。迭代计算时,考虑样本数据值的统计特性、数据序列间距关系。在对Massachusetts General Hospital/Marquette Foundation(MGH/MF)Waveform Database的数据进行算法测试后表明:该迭代算法具有快速、有效性和强壮性。 This paper presents an accurate method to detect the onset and peak points in arterial blood pressure waves. The sample data is processed by a slope sum function, and the onset and peak points for each wave period are determined in an iterative manner. The method takes into account the statistics of the sample data and relationship among the annotated point series. Experiments have been done on the Massachusetts General Hospital/Marquette Foundation(MGH/MF) Waveform Database, showing high speed, effectiveness and robustness of the method.
作者 迟冬祥 徐刚
出处 《上海电机学院学报》 2011年第4期223-226,共4页 Journal of Shanghai Dianji University
基金 上海市教育委员会科研创新项目(08YZ192) 上海电机学院重点学科资助(10XKF01) 上海电机学院重点培育项目资助(10C104)
关键词 动脉血压波 迭代检测 标记 arterial blood press ure(ABP) wave iterative detection annotation
  • 相关文献

参考文献15

  • 1Sorvoja H. Noninvasive blood pressure pulse detection and blood pressure determination[M]. Oulu: Oulun Yliopisto, 2006.
  • 2McCormick D, Budgett D M, Lim K M, et al. Frequency response of implantable blood pressure telemetry systems [J]. Clinical and Experimental Pharmacology and Physiology, 2010,37(8): 862-869.
  • 3Mills P A, Huetteman D A, Brockway B P, et al. A new method for measurement of blood pressure, heart rate, and activity in the mouse by radiotelemetry [J]. Journal of Applied Physiology, 2000,88 (5) : 1537-1544.
  • 4Kramer K, Voss H P, Grimbergen J A, et al. Telemetric monitoring of blood pressure in freely moving mice: a preliminary study [J]. Laboratory Animals, 2000,34(3) : 272-280.
  • 5Braga V A, Prabhakar N R. Refinement of telemetry for measuring blood pressure in conscious rats [J]. Journal of the American Association for Laboratory Animal Science, 2009, 48(3): 268-271.
  • 6Korpas D, Halek J, Dolezal L. Parameters describing the pulse wave [J]. Physiological Research, 2009,58(4): 473-479.
  • 7Karamanoglu M. A system for analysis of arterial blood pressure waveforms in humans[J]. Computers and Biomedical Research. 1997,30(3) : 244-255.
  • 8Nenova B, Iliev I. An automated algorithm for fast pulse wave detection[J]. International Journal. Bioautomation, 2010, 14(3): 203-216.
  • 9Aboy M, McNames J, Thong T, et al. An automatic beat detection algorithm for pressure signals [J]. IEEE Transactions on Biomedical Engineering, 2005,52(10) : 1662-1670.
  • 10Zong W, Heldt T, Moody G B, et al. An open-zource algorithm to detect onset of arterial blood pressure pulses [J]. Computers in Cardiology, 2003: 259-262.