摘要
分析了UNITANK工艺生物除磷的认识误区,在此基础上总结了UNITANK工艺强化生物脱氮除磷运行矩阵设置的基本原则,试验得出了UNITANK工艺强化生物脱氮除磷的核心控制矩阵和工艺运行控制参数,污水厂年度运行结果表明其出水水质稳定达到城镇污水处理厂污染物排放标准(GB 18918—2002)的一级B标准。
On the basis of analyzing the misunderstanding of biological dephsphorization by UNITANK process ,the basic principles of establishing the running matrix of enchanced biological denitrogenation dephosphorization by UNITANK have been summarized. By full-scale tests ,the core control matrix and the control parameters of technical operation of it have been obtained. The annually running results of the sewage treatment plant show that the effluent water quality is stable and meets the requirements of the first class of Standard B of Pollutant Discharge from Sewage Treatment Plants in Cities and Towns (GB 18918--2002).
出处
《工业水处理》
CAS
CSCD
北大核心
2011年第9期41-43,共3页
Industrial Water Treatment
基金
广东省教育部产学研结合项目(2010B090400441)