期刊文献+

SPR检测器在流动分析系统的应用

Application of SPR detector for flow analysis system
下载PDF
导出
摘要 为实现通用性强、样品消耗小、成本低新型检测器的开发,设计一种应用于流动分析体系的表面等离子共振(SPR)检测器.以3种糖的标准溶液为样品,开展检测器性能指标测试,得到相对标准偏差(RSD)值在1.3%以下,D-木糖、蔗糖、葡萄糖的检测下限分别为92、123、132ng,在最低检测限至10 000mg/L的检测范围内,线性拟合相关系数大于0.999.将SPR检测器作为液相色谱系统的检测器,测得分离后标准样品RSD值在2.3%以下,蔗糖和半乳糖的检测下限分别为6、9μg.结果表明,SPR检测器对于紫外检测或荧光检测不敏感,或者需要通过衍生化才可进行测量的成分,具有优势. To develop a novel detector with characteristics of versatility,low sample consumption,and inexpensiveness,surface plasma resonance(SPR) detector was designed for flow analysis system.Its performance was evaluated using 3 glucide solutions..Results showed that the RSD values were below 1.3%,and the detection limits of D-xylose,sucrose and glucose were 92,123,and 132 ng,respectively.The linearities of three components were excellent between detection limits and 10000 mg/L with correlation coefficients above 0.999.The SPR detector was applied to the liquid chromatography system.The RSD values were below 2.3% for separated samples with standard concentration solutions,it could detect the sucrose and galactose as low as 6 and 9 μg,respectively.It indicates that the detector is preponderant to detect materials insensitive to the ultraviolet detection or fluorescence detection,or which only can be detected by derivatization.
出处 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2011年第8期1480-1484,共5页 Journal of Zhejiang University:Engineering Science
基金 国家"863"高科技研究发展计划资助项目(2007AA09Z114) 浙江省科技计划资助项目(2007C13066)
关键词 表面等离子共振 流动分析体系 检测器 色谱分离系统 糖类 surface plasma resonance flow analysis system detector chromatography glucide
  • 相关文献

参考文献1

二级参考文献7

  • 1刘小林.SPR生物传感器研究综述[J].宜春学院学报,2006,28(4):120-123. 被引量:2
  • 2STENBERG E, PERSSON B, ROOS H, et al. Quantitative determination of surface concentration of protein with surface plasmon resonance using radiolabeled proteins [J]. Journal of Colloid and Interface Science, 1991, 143(2) : 513 - 526.
  • 3SHANKARAN D R, GOBI K V, MIURA N. Recent advancements in surface plasmon resonance immunosen- sots for detection of small molecules of biomedical, food and environmental interest [J]. Sensors and Actuators B, 2007, 121(1): 158-177.
  • 4BILITEWSKI U. Can affinity sensors be used to detect food contaminants? [J].Analytical Chemistry, 2000, 72 (21) : 692A - 701A.
  • 5JOHNSSON B, LOFAS S, LINDQUIST G. Immobilization of proteins to a carboxymethyl dextran modified gold surface for biospecific interaction analysis in surface plasmon resonance sensors [J]. Analytical Biochemistry, 1991, 198(2) : 268 - 277.
  • 6DHAR T K, SAMANTA A K, ALI E. Homogeneous enzyme immunoassay of estradiol using estradiol-3-o-carboxymethyl ether as hapten [J]. Steroids, 1988, 51(5/ 6) : 519 - 526.
  • 7赵晓君,陈焕文,宋大千,牟颖,张寒琦,金钦汉.表面等离子体子共振传感器I:基本原理[J].分析仪器,2000(4):1-8. 被引量:40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部