期刊文献+

双源CT诊断痛风性关节炎临床分析 被引量:16

Evaluation of dual-energy CT in patients with gout
原文传递
导出
摘要 目的采用非侵入性双源CT观察关节及周围组织的尿酸盐结晶,以探索临床诊断痛风或鉴别诊断其他关节疾病。方法选择近2周发作过单关节肿或(和)痛患者17例,均行病变关节双源CT检查。部分患者在B超下穿刺取关节液镜检。结果13例痛风患者发现33处有尿酸盐结晶,最常沉积的关节部位为双侧足趾关节(7/33)、近端指关节(5/33)、远端指间关节周围(4/33)、跖关节(4/33)、胫骨下端(3/33)。发现尿酸盐结晶易沉积在近关节骨表面,肌肉、韧带等关节周边软组织。关节肿痛部位与尿酸盐结晶沉积部位一致。尿酸盐结晶大小可以测量。结论双源CT可以清晰显示尿酸盐结晶,为无创检测手段。在鉴别诊断不明原因单关节肿痛方面有很好的价值。 Objective To explore the value of non-invasive dual-energy CT in the diagnosis of gout and the differential diagnosis of other joint diseases by observing urate crystals surrounding tissues. Methods Seventeen patients, who experienced unilateral arthrocele or joint pain in the past two weeks, were enrolled into our study. Dual-energy CT was performed in all patients and ultrasound-guided joint aspiration were performed in some patients. The location, quantity and size of urate crystals were analyzed by dual-energy CT. Results Thirty-three urate crystals were found in 13 gout patients, and the most common sites of deposition were bilateral inter-phalangeal joints of foot (7/33), proximal inter-phalangeal joints (5/33), tissues around distal interphalangeal joint (4/33), metatarsal joints (4/33) and the lower part of the tibia (3/33). The data indicated that urate crystals were more likely to deposit in the soft tissues around joints such as muscles, ligaments and so on, and the sites of deposition were consistent with the locations of arthralgia. The size of urate crystals could also be measured by dual-energy CT. Conclusion Urate crystals can be displayed by dual- energy CT. In addition, dual-energy CT is a non-invasive measure and it has great value in the differential diagnosis of joint diseases.
出处 《中华风湿病学杂志》 CAS CSCD 北大核心 2011年第9期638-639,I0006,共3页 Chinese Journal of Rheumatology
关键词 体层摄影术 X线计算机 关节炎 痛风性 诊断 Tomography, X-ray computed Arthritis, gouty Diagonsis
  • 相关文献

参考文献3

  • 1Nicolaou S, Yong-Hing C J, Galea-Soler S, et al. Dual-energy CT as a potential new diagnostic tool in the management of gout in the acute setting. AJR, 2010, 194: 1072-1078.
  • 2Choi HK, Curhan G. Soft drinks, fructose consumption, and the risk of gout in men: prospective cohort study. Br Med J, 2008, 336: 309-312.
  • 3Choi HK, Al-Arfaj AM, Eftekhari A, et al. Dual energy computed tomography in tophaceous gout. Ann Rheum Dis, 2009, 68: 1609-1612.

同被引文献148

  • 1李长勤,付建斌,孙庆举,谢元忠.痛风性关节炎的影像学诊断[J].泰山医学院学报,2006,27(5):384-386. 被引量:11
  • 2Pascual E, Sivera F, AndrOs M. Synovial fluid analysis for e-'stals. Curt Opin Rheumatol,2011,23:161-169.
  • 3Romanoff NR, Canoso J J, Rul-inow A.et al. Gout without crystals on initial syn.vial fluid analysis. Postgrad Med J, 1978,54:95-97.
  • 4Nero P, Nogueira 1, Vilar R, et al. Synovial fluid crystal identification by electron microscopy. Acla Reumatol Port,2006, 31:75-81.
  • 5Glazebrook KN, Guimaraes 1,S, Murlhy NS,et al. Identification of intraarticular and periarticular uric' a id crystals with dual-energy CT: initial evaluation. Radiology,2011,261:516-524.
  • 6Dalbeth N. l)oyle A. Boyer I: et al. Development of a ,'omputed tomography method of scoring hone erosion in patients with gout: wtlidation and clinical implicalions. Rheumatology (Oxford), 201 t ,50:410-416.
  • 7Dalbelh N, Schauer C, Macdonald P, el al. Methods of tophus assessment in clinical trials of chronic goul : a syslematic literature review and pictorial reference guide. Ann Rheum Dis,2011,70 : 597 -604.
  • 8Thiele RG. Role of ultras-und and other advanced imaging in tht" diagnosis and management of gout. Curt Rheumatol Rep, 2011, 13 : 146-153.
  • 9Karqaahincaba M, Akta- A. Dual-energy CT revisited with multidelector CT: review of principles and clinical applications. Diagn lnlerv Radiol, 2011,17 : 181-194.
  • 10Manger B, l.ell M, 'W acker J, et al. Detection og periarticular urate deposits with dual energy CT in patients with aeule gouty arthritis. Ann Rheum Dis,2012,71:470-472.

引证文献16

二级引证文献112

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部