期刊文献+

320排CT高管电压在低剂量扫描中的应用 被引量:5

Application of high tube voltage in low dose CT scan with 320-slice CT
下载PDF
导出
摘要 目的探讨管电压对320排CT颅脑扫描辐射剂量及图像质量的相关影响,优化CT低剂量扫描参数。方法随机把60例颅脑平扫受检者分成3组,每组20例。分别以100 kV,400 mAs、120 kV,220 mAs和135 kV,160mAs进行扫描。记录不同管电压扫描的辐射剂量长度乘积(DLP),测量扫描所得图像中豆状核和丘脑区的CT值标准差,并由两位副主任医师对图像质量进行盲法评分,对比分析不同管电压CT扫描的辐射剂量及图像质量。结果 3组辐射剂量长度乘积(DLP)100kV组为601.7mGy,120kV组为551.0mGy,135kV组为533.8mGy,135kV组明显低于100kV组。3组图像质量差异无统计学意义(P>O.05),结论高管电压颅脑CT扫描,有助于降低扫描辐射剂量。 Objective To assess the influence of different tube voltage on image quality and scanning radiation does with 320-slices CT to optimize the low dose CT scan parameters. Methods 60 patients were devided into 3 groups randomly. Patients in group A, B and C received scanning with the tube voltage and tube current as 100 kV 400 mAs, 120 kV, 220 mAs, 135 kV and 160mAs, respectively. Radiation dose length product (DLP) was recorded and the standard deviation of CT value in lenticular nucleus and thalamus was acquired. The image quality with different scanning parameters was assessed by two associate chief physicians blindly. Results DLP of the three group was 601.7 mGy, 551.0 mGy and 533.8 mGy. DLP of group C was significantly lower than those of group A. And there is no no statistically significant differences (P〉0.05)on and the image quality among the groups. Conclusion High voltage CT scans can decrease the does of CT scan without lowering the image quality.
出处 《影像诊断与介入放射学》 2011年第4期255-257,共3页 Diagnostic Imaging & Interventional Radiology
关键词 体层摄影术 X线计算机 容积扫描 高管电压 低剂量 High voltage 320-slice volumetric CT Low dose
  • 相关文献

参考文献10

二级参考文献41

  • 1刘昌盛,魏文洲,郑晓华,童世平,殷响林,杨洪飙.低剂量CT扫描对婴幼儿颅脑病变检查的防护价值[J].中华放射医学与防护杂志,2004,24(3):270-271. 被引量:67
  • 2邓大平,张贵林,朱建国,杜希成.CT检查剂量与防护[J].中国辐射卫生,2004,13(4):309-310. 被引量:8
  • 3干芸根,荣远新,李荫太,向葵,徐大勇,林飞飞,孙洁,谢娜.螺旋CT低剂量胸部扫描技术在儿童气管病变中的应用[J].中华放射医学与防护杂志,2006,26(4):405-407. 被引量:22
  • 4张煊 石磊 等.CT机临床照片影像状况及缺陷归因分析.全国大型医用设备应用技术研讨会论文集[M].北京,2000.149-151.
  • 5Smith RC,Rosenfield AT,Choe KA,et al.Acute flank pain:comparison of noncontrast-enhanced CT and intravenous urography.Radiology,1995,194(3):789-794.
  • 6Spielmann AL,Heneghan JP,Lee LJ,et al Decreaseing the radiation dose for renal stone CT:a feasibility study of single and multi-detector CT.AJR Am J Roentgenol,2002,178(5):1058-1062.
  • 7Joan P,Keith A,Richard A,et al.Helical CT for Nephrolithiasis and Ureterolithiasis:Comparison of Conventional and Reduced Radiation-Dose Techniques.Radiology,2003,229(2):575-580.
  • 8Liu W,Esler SJ,Kenny BJ,et al.Low-dose nonenhanced helical CT of renal colic:assessment of ureteric stone detection and measurement of effective dose equivalent.Radiology,2000,215(1):51-54.
  • 9Diel J,Perlmutter S,Venkataramanan N,et al.Unenhanced helical CT using increased pitch for suspected renal colic:an effective technique for radiation dose reduction?J Comput Assist Tomogr,2000,24(5):795-801.
  • 10Naidich DP,Marshall CH,Gribbin C,et al.Low-dose CT of the lung:prelimary observations.Radiology,1990,175(3):729-731.

共引文献39

同被引文献44

引证文献5

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部