摘要
文中详细分析了珠海发电厂空预器上导轴断裂及轴承箱漏油的原因,并对空预器进行了相关的改造,空预器经改造后,解决了上导轴断裂及轴承箱漏油的缺陷,满足了机组安全稳定运行的要求。
The reasons of top guide bearing cracking and bearing box oil-leakage for air preheater in Zhuhai Power Plant are analyzed detailedly,relevant renovation is performed on air preheater to solve the disadvantage and satisfy the requirement of safe and stable operation of the unit.
出处
《锅炉制造》
2011年第5期56-58,共3页
Boiler Manufacturing
关键词
空预器
上导轴
支撑臂
断裂
漏油
air preheater
top guide bearing
bearing beam
cracking