摘要
在船体外加电流阴极保护系统中,由于各种故障,经常引起系统不能正常工作。在工作中发现在船用恒电位仪相关标准中"输入阻抗≥1 MΩ"指标制定的偏低,在此进行了探讨。同时还从使用维修时出现的问题和提高系统可靠性的角度提出了设计和维修的改进意见。
Marine impressed current cathodic protection system often works improperly because of different defects. This thesis discusses the standard which is found a little lower in the input impedance ≥1MΩ in marine potentiostat relevant standards during daily work. And it also puts forward the procedure of design and repair according to defects in operation and maintenance in order to increase system reliability.
出处
《中国修船》
2011年第5期40-42,共3页
China Shiprepair
关键词
船体阴极保护
恒电位仪
参比电极
输入阻抗
设计和修理
cathodic protection for ship hull
potentiostat
reference electrode
input impedance
design and repair