期刊文献+

周围神经刺激仪在臂丛神经阻滞中的应用 被引量:2

The application of the peripheral nerve stimulation in brachial plexus block
下载PDF
导出
摘要 目的:比较神经刺激仪定位与传统异感法定位臂丛神经阻滞的麻醉效果。方法:选择上肢手术患者60例,ASAⅠ~Ⅱ级,随机分2组,每组30例。Ⅰ组采用神经刺激仪进行定位操作,以胸大肌、三角肌、肱二头肌收缩反应其中之一出现作为穿刺针正确定位标志;Ⅱ组采用传统找异感法进行臂丛神经阻滞,阻滞药用0.25%罗哌卡因。观察并记录2组臂丛神经阻滞效果和并发症情况。结果:Ⅰ组臂丛神经阻滞效果优于Ⅱ组(P(0.05),而并发症低于Ⅱ组(P(0.05),差异均有统计学意义。结论:神经刺激仪引导定位行臂丛神经阻滞,显著提高麻醉效果,且减少麻醉并发症。 Objective: comparing nerve stimulation paresthesia location and orientation of traditional brachial plexus block anesthesia.Method:60 patients with upper extremity surgery,ASA LevelⅠ~Ⅱ,were randomly divided into 2 groups with 30 each.GroupⅠ was treated with a nerve stimulator to locate operations to pectoralis major,deltoid,biceps contraction of one of the correct positioning of the needle appears as a symbol;GroupⅡ using the traditional method to find different sense of brachial plexus block,block medical ropivacaine 0.25%.2 groups were observed and recorded the brachial plexus block effects and complications.Result:The fine brachial plexus block in GroupⅠ is higher than that of group Ⅱ(P0.05),and the complications in Group Ⅰ were lower than that of group Ⅱ(P0.05),the differences were statistically significant.Conclusion:The nerve stimulator guided brachial plexus block positioning line,significantly increased anesthetic effect,and reduced anesthetic complications.
出处 《赣南医学院学报》 2011年第4期569-570,共2页 JOURNAL OF GANNAN MEDICAL UNIVERSITY
关键词 神经刺激仪 臂丛神经阻滞 罗哌卡因 Nerve stimulator brachial plexus block ropivacaine
  • 相关文献

参考文献4

二级参考文献25

  • 1陈开文,张传汉,罗敏,孙继领.神经刺激器在臂丛神经阻滞的应用[J].临床麻醉学杂志,2005,21(11):798-799. 被引量:16
  • 2J ochum D,Iohom G, Diarra DP, et al. An objective assessment of nerve stimulators used for peripheral nerve blockade. Anaesthesia, 2006,61 : 557-564.
  • 3Sukhani R, Candido KD. Interscalene brachial plexus block: shoulder paresthesia versus deltoid motor response: revisiting the anatomy to settle the controversy. Anesth Analg, 2002, 95 : 1818-1819.
  • 4Silverstein WB, Saiyed MU, Brown AR. Interscalene block with a nerve stimulator: a deltoid motor response is a satisfactory endpoint for successful block. Reg Anesth Pain Med, 2000,25:356-359.
  • 5Tonidandel WL, Mayfield JB. Successful interscalene block with a nerve stimulator may also result after a pectoralis major motor response. Reg Anesth Pain Med, 2002,27:491-493.
  • 6Lenters TR, Davies J, Matsen FA 3rd. The types and severity of complications associated with interscalene brachial plexus block anesthesia:local and national evidence. J Shoulder Elbow Surg,2007,16:379 387.
  • 7[1]Jacques E.Chelly,eds.Peripheral nerve blocks.Baltimore:Williams and Wikins,1999.7-10.
  • 8[2]Winnie AP,Ramamurthy S,Durrani Z,Radonjic R.Plesus blocks for lower extremity surgery.Anesthesiology Review,1974,00:11-16.
  • 9[3]Mcleod DH,Wang DHW,Claridge RJ:Lateral popliteal sciatic nerve block compared with subcutaneous infiltration for analgesia following foot surgery.Can J Anaesth.1994,41:673-676.
  • 10[4]Coveney E,Weltz CR,Greengrass R,et al.Use of paravertebral block anesthesia in the surgical management of breast cancerr.Ann Surg,1998,227:496-501.

共引文献133

同被引文献11

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部