期刊文献+

SSH-TSE结合SENSE技术在MR检查中消除头部运动伪影的应用 被引量:2

下载PDF
导出
摘要 目的探讨SSH-TSE结合SENSE序列在消除MRI运动伪影的应用价值。方法分析36例应用SSH-TSE结合SENSE进行MR扫描,并与常规TSE序列T2WI扫描的图像进行比较。结果 36例应用SSH-TSE结合SENSE进行头部T2WI扫描的图像明显减少或消除了运动伪影(P<0.05)。结论在MR检查过程中,对于不合作的患者应用SSH-TSE与SENSE相结合的成像技术能够极大的缩短扫描时间,提高检查成功率,减少由于运动造成的伪影,为医生提供更有利于观察的影像资料。
作者 范晓娟
出处 《河北医药》 CAS 2011年第19期2962-2963,共2页 Hebei Medical Journal
  • 相关文献

参考文献5

  • 1钱根年,陈自谦,许尚文,肖慧,倪萍.探讨PROPELLER和SSFSE扫描技术在颅脑MR成像中应用价值[J].医学影像学杂志,2007,17(4):333-336. 被引量:5
  • 2Pruessman KP, Wneikgper M, Scheidegger MB, et al. SENSE : sensitivity encoding for fast MRI. Magn Reson Med ,1999 ,42 :952-962.
  • 3Hoffmann KT, Hoster N, Ehrenstein T, et al. The T2-weighted half-Fourier acquired single-shot turbo-spin-echo technic compared to the conventionalT2-weighted turbo-spin-echo technic for cerebral magnetic resonace tomography. A sequence comparison. Rofo,2000,172:521-526.
  • 4BammerR, Keeling SL, Au M, et al. Improved diffuweighted single-shot echoimaging in stroke ussitivity encoding. Reson Med ,2001,46:548.
  • 5Weiger M, Pruessmann KP, Leussler L, et al. Specific coil design for SENSE:six-element cardiaarray. Magn Reson Med ,2001,45:495-504.

二级参考文献7

  • 1秦文,于春水,李坤成.螺旋桨(PROPELLER)技术的原理及应用[J].医学影像学杂志,2005,15(10):912-915. 被引量:24
  • 2戈明媚,王秋良,刘志钦,刘晓林,廖玉珍,孙玮,孙楠,张英魁.MR螺旋桨扫描技术在消除伪影方面的临床应用[J].中华放射学杂志,2006,40(2):208-212. 被引量:37
  • 3American academy of pediatrics committee on drugs.Guidelines for monitoring and management of pediatric patients during and after sedation for diagnostic and therapeutic procedures[J].Pediatrics,1992,89:1110-1115.
  • 4Meyer CH,Hu BS,Nishimura DG,et al.Fast spiral coronary artery imaging[J].Magn Reson Med,1992,28:202-213.
  • 5Pipe JG.Motion correction with PROPELLER MRI:application to head motion and free-breathing cardiac imaging[J].Magn Reson Med,1999,42:963-969.
  • 6Kirsten PN,Forbes,JG,Pipe C,et al.PROPELLER MRI:clinical testing of a novel technique for quantification and compensation of head motion[J].Magn Reson Imaging,2001,14:215-222.
  • 7Kirsten P,Forbes,JG,Pipe JP.Brain imaging in the unsedated pediatric patient comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences[J].AJNR,2003,24:794-798.