介绍了化工空分自控系统中的三个典型的故障处理,看似复杂的故障,真实原因可能很简单,主要是图纸不规范、安装不规范,设计考虑不周、选型不恰当等细小环节造成的。设计严谨、安装规范、注重细节对自控系统非常重要。
Describes the chemical air separation in the three typical automatic control system troubleshooting, seemingly complex fault, the real reason may be very simple, mainly drawings are not standardized, non-standard installation, design ill-considered, inappropriate selection and other small areas result. Rigorous design, installation practices, attention to detail is very important for the automatic control system.