期刊文献+

气相色谱法测定空气中环氧乙烷 被引量:8

GC Determination of Ethylene Oxide in Air
下载PDF
导出
摘要 用气相色谱法对空气中环氧乙烷进行了测定。采用徽章式扩散型被动式采样器采集了车间空气中的环氧乙烷,采集到的环氧乙烷在采样器中转化生成稳定的2-溴乙醇,再用二氯甲烷-甲醇(10+90)溶液进行萃取,分取此溶液1.0“L直接进样进行气相色谱分析,根据测定溶液中2-溴乙醇的量来确定空气中环氧乙烷的含量。环氧乙烷的质量浓度在2.8~33.6mg·L-1范围内与峰面积呈线性关系,方法的检出限(3S/N)为0.38mg·L-1。方法的回收率在81.8%~92.3%之间,相对标准偏差(n=6)均小于5%。 Ethylene oxide in air was determined by gas chromatography. The ethylene oxide in air of workshop was sampled by using passive diffusion air monitoring badge as sampler, and converted into stable 2 bromoethanol. A mixture of CH2 Cl2 CH3 OH(10+90) was used to extract 2-bromoethanol from the sampler and 1.0μL of the extract was taken for GC analysis. The amount of 2-bromoethanol found was converted into content of ethylene oxide. Linear relationship between values of peak area and mass concentration of ethylene oxide was found in the range of 2. 8--33.6 mg ·L-1, with its detection limit (3S/N) of 0. 38 mg ·L-1. Test for recovery was made by standard addition method, giving results of recovery in the range of 81.8%--92.3% . Values of RSD's (n=6) found were less than 5%.
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2011年第9期1058-1059,1062,共3页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 气相色谱法 被动式采样器 空气 环氧乙烷 GC Passive diffusion air monitoring badge sampler Air Ethylene oxide
  • 相关文献

参考文献3

二级参考文献2

共引文献6

同被引文献46

引证文献8

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部