摘要
涂料经溶剂提取或涂膜经索氏提取后,提出液中邻苯二甲酸酯类单体DEHP、DBP、BBP、DNOP可用DB-130.0m×φ0.25mm×0.5μm色谱柱同时分离,GC-FID或GC-MSD全扫描测定,DINP、DIDP宜采用GC-MSD选择离子扫描单独测定。采用GC-MSD测定时,方法的回收率不低于95%,DEHP、DBP、BBP、DNOP的最小检出限(LODs)均为0.04μg/mL,最低定量限(LOQ)均为0.35μg/mL。选择扫描时,DINP、DIDP的LODs、LOQ分别为0.4μg/mL、3.5μg/mL。实验结果表明:某些丙烯酸树脂涂料以及手机外壳涂层含有高含量生殖致癌物PAEs类单体,应为制定手机涂料中邻苯二甲酸酯类有害物质最高允许限量进行评价。
After coating film was extracted by DBP, BBP, DNOP, DINP and DIDP in extraction DB-1 30.0 m×Ф0. 25 mm×0.5μm. Those four soxhlet method, phthalate ester compounds of DEHP, solution could be separated by chromatographic column compounds (DEHP, DBP, BBP and DNOP) could be determined using Flame Ionization Detector (FID) or Mass Spectrograph Detector (MSD), whereas the oth- er two compounds (DINP and DIDP) could only be measured using MSD with Selected Ion Monitoring (SIM). For DEHP, DBP, BBP and DNOP, when MSD was employed as detector, the limits of detection (LODs) were 0. 04 μg/mL and the limits of quantity (LOQs) 0.35 μg,/mL for all for DINP and DIDP, the LODs were 0. 04 μg/mL, and the LOQs were 3.5 μg/mL. The results of the experiment (s) showed that carcinogenic PAEs exists in members of the acrylic resin coatings and film coat of mobile, Therefore its necessary to conduct safety evaluation and establish the allowable maximum concentration in mobile coatings.
出处
《涂料工业》
CAS
CSCD
北大核心
2011年第10期62-66,共5页
Paint & Coatings Industry
关键词
手机涂料
涂膜
邻苯二甲酸酯
测定
评价
mobile coating
paint films
phthalate ester
determination
safety evaluation