期刊文献+

敏感设备电压暂降失效率区间最大混合熵评估 被引量:17

Estimation of maximum interval hybrid entropy of sensitive equipment failure rate due to voltage sag
下载PDF
导出
摘要 考虑设备故障状态的过渡过程,将正常和完全故障以外的状态归结为不完全故障状态,对设备在电压暂降作用下发生失效的可能性进行了评估。首先通过区间数刻画敏感设备电压耐受能力,结合供电端暂降发生的随机性,确定电压暂降作用下设备可能发生的非正常状态概率区间。为更全面考虑实际存在的复杂不确定性,利用混合熵能综合考虑供电端电压暂降的随机性和模糊性的特点,建立区间概率最大混合熵模型,在给定约束条件下识别满足熵值最大原理的分布,作为设备敏感度的评估测度,以此得到设备失效率的点值评估结果。利用实测PC机电压暂降失效率数据进行对比,发现在小样本情况下得到的结果能达到相当高的精度。最后以33节点配电网为例进行仿真,证明方法的正确性。 According to the transition process of equipment fault status ,all kinds of status excluding normal and complete fault status are considered as incomplete fault status and the possibility of equipment failure due to voltage sag is evaluated. The voltage tolerance level of sensitive equipment is characterized by the interval data and,combined with the randomness of voltage sag,the interval possibility of incomplete fault status is determined. To more comprehensively take the complexity and uncertainty into account,the hybrid entropy is used to measure the randomness and fuzziness of practical voltage sag and the model of maximum interval hybrid entropy is developed to estimate the equipment sensitivity under certain conditions and to obtain the point probability of equipment failure rate. Comparison with the measured data of personal computer failure rate due to voltage sag shows that ,the results in small samples are quite accurate. The simulation for IEEE 33-bus system proves the effectiveness of the introduced method.
出处 《电力自动化设备》 EI CSCD 北大核心 2011年第10期70-75,共6页 Electric Power Automation Equipment
基金 国家自然科学基金资助项目(50877049)~~
关键词 电压暂降 设备敏感度 区间概率 失效率 点值概率 模型 电能质量 评估 voltage sag equipment sensitivity interval probability entropy failure rate point probability models power quality estimation
  • 相关文献

参考文献29

  • 1CLARK W,GELLINGS P E. The smart grid:enabling energy efficiency and demand response[M]. London,UK:Taylor & Francis Ltd, 2009 : 218-325.
  • 2MILANOVIC J V,GUPTA C P. Probabilistic assessment of financial losses due to interruptions and voltage sags-part I :the methodology[J]. IEEE Trans Power Del,2006,21(2):918-924.
  • 3肖先勇,杨洪耕,陈武,李华强.敏感设备电压暂降敏感度的模糊随机评估[J].中国电机工程学报,2009,29(34):90-95. 被引量:49
  • 4HALMOS P R. Measure theory[M].北京:世界图书出版公司,2007:30-44.
  • 5GUPTA C P,MILANOVIC J V. Probabilistie assessment of equipment trips due to voltage sags [J]. IEEE Trans Power Del, 2006,21 (2) :711-718.
  • 6肖先勇,马超,杨洪耕,李华强.用电压暂降严重程度和最大熵评估负荷电压暂降敏感度[J].中国电机工程学报,2009,29(31):115-121. 被引量:59
  • 7MILANOVIC J V,GUPTA C P. Probabilistic assessment of financial losses due to interruptions and voltage sags-part Ⅱ^+: practical implementation[J]. IEEE Trans Power Del,2006,21(2): 925-932.
  • 8肖先勇,王希宝,薛丽丽,刘波,杨洪耕.敏感负荷电压凹陷敏感度的随机估计方法[J].电网技术,2007,31(22):30-33. 被引量:52
  • 9LU Channan,SHEN Chengchieh. Estimation of sensitive equipment disruptions due to vohage sags[J]. IEEE Transactions on Power Delivery,2007,22(2) : 1132-1137.
  • 10陈铁敏,杨洪耕.基于改进故障点法的电压凹陷评估[J].电力自动化设备,2008,28(6):66-69. 被引量:13

二级参考文献150

共引文献226

同被引文献319

引证文献17

二级引证文献184

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部