低压无功功率补偿装置的动态响应试验 被引量:4

Dynamic Response Test of Low Voltage Reactive Power Compensation Assemblies
下载PDF
导出
摘要 介绍了低压电容补偿装置的工作原理和应用,分析了具体的试验过程试验波形图,阐述了试验目的和必要性,比较了带复合开关的无功功率补偿装置与带接触器的无功功率补偿装置的动态响应试验。分析了其动态响应试验要求差别的原因与关键,总结了不同补偿方式在无功功率补偿装置的选择要依电网的状况,补偿的线路及负载等因素而定。 The working principle and application of low voltage reactive power compensation assemblies were introduced.The test was analyzed by waveform.The purpose and necessity of the test were described.The dynamic responce test of reactive power compensation assemblies with composite swich and with contactors were compared.The tests difference and main reason were analyzed.The different ways of compensation were summarized which depend on the status of power,compensation line,load and so on.
出处 《低压电器》 北大核心 2011年第18期50-52,共3页 Low Voltage Apparatus
关键词 无功功率补偿装置 动态响应试验 静态补偿 reactive power compensation assemblies dynamic response test static compensations