期刊文献+

Mtwo机用镍钛器械根管预备的临床应用 被引量:5

下载PDF
导出
摘要 在根管治疗过程中,根管预备成形是决定根管治疗成败的关键因素之一。Mtwo机用镍钛锉是一种新型的具有特殊锥度的根管预备器械,独特的设计使其具有良好的柔韧性、切削能力和安全性。本文分别使用Mtwo机用镍钛锉和传统不锈钢K锉进行根管预备,比较两者的临床疗效,报道如下。
出处 《安徽医科大学学报》 CAS 北大核心 2011年第10期1107-1108,共2页 Acta Universitatis Medicinalis Anhui
  • 相关文献

参考文献5

  • 1Abou-Rass M, Jastrab R J. The use of rotary instruments as auxil- iary aids to root canal preparation of molars[ J]. J Endod, 1982,8 (2) :78 -82.
  • 2Ehrmann E H,Messer H H, Adams G G. The relalionship of intra- canal medicaments to postoperative pain in endodontics [ J ]. Int Endod J,2003,36(12) :868 -75.
  • 3Luiten D J, Morgan L A, Baugartner J C, et al. A comparison of four instrumentation techniques on apical canal transportation [ J ]. J Endod, 1995,21 ( 1 ) :26 -32.
  • 4郭惠杰,梁宇红,王嘉德.两种机用镍钛器械根管预备的临床应用研究[J].现代口腔医学杂志,2009,23(3):235-238. 被引量:13
  • 5吴冰,张黎,赵春晖.超声根管与手动根管治疗的临床对比研究[J].安徽医科大学学报,2003,38(5):394-395. 被引量:4

二级参考文献16

  • 1Smith CS, S techell DI, Harry FJ. Factors influencing the success of conventional root canal therapy - a 5 - year retrospective study. Int Endo J, 1993,26:321 - 333.
  • 2Yun HH, Kim SK. A comparision of the shaping abilities of 4 nickel -titanium rotary instruments in simulated root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Ended ,2003,95:228 -233.
  • 3Krupp JD, Brantley WA, Gerstein H. An investigation of the torsional and bending properties of seven brands of endodontie f'des. Jof Endod, 1984, 9:372 - 380.
  • 4Schneider SW. A comparision of canal preparation in straight and curved root canals. Oral Surg Oral Med Oral Pathol ,1971,32:271 - 275.
  • 5About- Rass M, Jastrab RJ. The use of rotary instruments as auxiliary aids to root canal preparation of molars. J of Endod, 1982, 8:78-82.
  • 6Luiten D J, Morgan LA, Baugartner JC, et al. A eomparision of four instrumentation techniques on apical canal transportation. J of Endod, 1995, 21:26 -32.
  • 7Buchanan IS. The standardized taper root canal preparation:part 1. concepts for variably tapered shaping instruments. Int Endod J, 2000, 33:516-529.
  • 8Yared GM. Behavior of Hero NITI instruments used by an experienced operator under access limitations. Aust Endod J, 2002, (2):64.
  • 9Thompson SA, Dummer MH. Shaping ability of Hero642 rotary nickel - titmfium instruments in simulated root canals: Patti. Int Endod J, 2000, 33 : 248 - 254.
  • 10Schafer E, Erler M, Dammaschke T. Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments: Part2. Shaping ability in simulated curved eanals, lnt Endod J, 2006, 39 : 196 - 202.

共引文献15

同被引文献46

二级引证文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部