摘要 德阳汇通大厦A栋II区是一个复杂连体结构。为了解结构的抗震性能,确定地震反应时的薄弱部位,提出加强措施,对该结构进行了空间模型下的抗震分析,包括模态分析和大震作用下的弹塑性时程分析,通过对位移、内力、应力等反应数据分析,发现结构满足延性设计要求,无明显薄弱层,抗震性能良好。 The area II of De Yang Huitong Building A is a complex connecting structure. In order to understand the seismic performance of the structure and determine the weak parts, then present enhancement measures, the seismic analysis of the structure under the space model were carried out, which includes model analysis and elastic-plastic time history analysis under major earthquake. At last, it is recognized that the structure can have a good seismic performance by the data of displacement, internal force, and stress.
出处 《工程建设与设计》 2011年第10期56-61,共6页 Construction & Design for Engineering
关键词 复杂连体结构 模态分析 弹塑性时程分析 结构抗震性能 complex connecting structure model analysis elastic-plastic time history analysis structure seismic performance
  • 相关文献

参考文献6

二级参考文献12

  • 1吕西林,朱杰江.高层建筑结构推覆分析及对设计的启示[J].建筑结构学报,2005,26(6):100-107. 被引量:7
  • 2安东亚,钱江,李冬梅.含剪力墙结构体系推覆分析中几个相关问题的对比研究[J].结构工程师,2007,23(1):19-23. 被引量:1
  • 3同济大学土木工程防灾国家重点实验室.舟山市普陀区东港商务中心1、2#楼结构模型模拟地震振动台试验研究报告[R].上海:同济大学,2008.
  • 4中华人民共和国建设部.JGJ 3-2002,J 186-2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2002.
  • 5薛焱涛,徐培福,肖从真,等.静力弹塑性分析(Push-over)方法及工程应用[C].第十八届全国建筑结构学术会议论文集.重庆:中国建筑科学研究院,2004.
  • 6黄吉峰,杨志勇,邵弘,等.结构静力弹塑性分析(Pushover)EPSA[C].第十八届全国建筑结构学术会议论文集.重庆:中国建筑科学研究院,2004.
  • 7康婧.超限复杂高层建筑的抗震分析.结构工程师,2007,.
  • 8徐自国.北京当代MOMA结构的抗震性能设计及静力弹塑性分析[C]//第十九届全国建筑结构学术会议论文集.长春,中国建筑科学研究院,2006.
  • 9中华人民共和国建设部.GB50011-2001建筑抗震设计规范[S].北京:中国建筑工业出版社,2001..
  • 10中华人民共和国建设部.JGJ3-2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2002.