期刊文献+

缺氧-好氧法+新型外置膜生物反应器处理乳品废水研究

STUDY ON THE A/O+ EXTERNAL MBR DEAL WITH DAIRY WASTEWATER SEWAGE
下载PDF
导出
摘要 利用缺氧-好氧法(A/O)+外置膜生物反应器(MBR)对乳品废水进行试验,MBR与A/O工艺结合,强化脱氮,利用气液混合泵曝气代替鼓风曝气。结果表明,气液混合泵充氧效率高、能耗低。进水COD和NH3-N、TN、TP质量浓度平均分别为994 mg.L-1和38.7、76.3、8.8 mg.L-1时,出水COD和NH3-N、TN、TP质量浓度平均分别为17.8mg.L-1和6.9、16、1.27 mg.L-1,去除率分别为98.2%和82%、78.9%、85.7%。 Use A/O+ new extemal MBR deal with dairy wastewater sewage, MBR Combination A/O process, in order to consolidate and nitrogen. Use aeration pump replace blowing aeration. Result, Into the water for COD, NH3-N, TN, TP averages 994 mg.L^-1, 38.7 mg.L-1, 76.3 mg.L-1, 8.8 mg.L-1; Effluent COD, NH3-N, TN, TP 17.8 mg.L^-1, 6.9 mg-L^-1, 16 mg.L^-1, 1.27 mg.L^-1; The averages removal rate are 98.2%, 82%, 78.9%, 85.7% respectively.
出处 《水处理技术》 CAS CSCD 北大核心 2011年第10期71-74,共4页 Technology of Water Treatment
基金 中科院知识创新工程重要方向项目(KZCX2-YW-421) 河南工业大学高层次人才基金(150329)
关键词 外置膜生物反应器 气液混合泵 缺氧-好氧法 external MBR aeration pump A/O process
  • 相关文献

参考文献11

二级参考文献17

  • 1张杰.水资源、水环境与城市污水再生回用[J].给水排水,1998,24(8).
  • 2国家环境保护局.水和废水监测分析方法[M].北京:中国环境科学出版社,1989.502-503.
  • 3陈永.阳离子型高分子絮凝直接过滤性能研究[学位论文].西安:西安建筑科技大学,1999..
  • 4马军.高锰酸钾去除与控制饮用水中有机污染物的效能与机理:[学位论文].哈尔滨:哈尔滨建筑工程学院,1987..
  • 5[1]GVIDAL G,CARVALHO A,MNDEZ R,et a1.1nfluence of the content in fats and proteins on the anaerobic biodegradability of dairy wastewater[J].Bioresource Technology,2000,74(3):231-239.
  • 6[3]Lee Hyung Sool,Park Se Jin,Yoon Tai Il.Wastewater treatment in a hybrid biological reactor using powdered minerals effects of organic loading rates on COD removal and nitrification[J].Process Biochemistry,2002,81(1):81-88.
  • 7[5]Fadi Gebara.Activated sludge biofilm wastewater treatment system[J].Wat Res,1999,33(1):230-238.
  • 8KOCH F A, OLDHAM W K. Oxidation-reduction potential - a tool for monitoring, control and optimization of biological nutrient removal systems[J]. War Sci Tech, 1985.17:259 - 281.
  • 9CHARPENTIER J, FLORENTZ M, DAVID G. Oxidation-reduction potential (ORP) regulation: a way to optimize pollution removal and energy savings in the low load activated sludge process [ J ]. Wat Sci Tech, 1987,19 :645 - 655.
  • 10WAREHAM D G, HALL K J, MAVINIC D S. Real-time control of wastewater treatment systems using ORP .War Sci Tech, 1993,28 (11 - 12) :273 -282.