摘要
对迈克尔逊干涉仪上形成的等效光源做详细的分析,指出等倾干涉条纹出现椭圆的原因并指明调整思路。
The formation of the equivalent light sources on Michelson interferometer is analysed in detail.The reason of the interference fringes appeared ellipse is pointed out and the adjusting method is stated.
出处
《安徽工业大学学报(自然科学版)》
CAS
2011年第4期410-412,共3页
Journal of Anhui University of Technology(Natural Science)
关键词
迈克尔逊干涉仪
等效光源
干涉条纹
椭圆
Michelson interferometer
equivalent light sources
interference fringes
ellipse