摘要 在对大唐红河发电有限公司300 MW循环流化床(CFB)锅炉特性分析的基础上,对一次风控制系统、运行方式、二次风配风、高压流化风系统等进行了优化。优化后,提高了一次风控制系统的调节品质和锅炉使用寿命,改善了炉膛燃烧,显著减少了过、再热蒸汽温度超温和机组非计划停运次数,降低了厂用电率,满足了电网对机组降负荷速率的要求。 Based on analysis of characters of boiler equipped for 300 MW unit in Datang Honghe Power Generation Co Ltd,the control system of primary air,the operation mode,and the distribution of secondary air,and the high-pressure fuidized air system have been optimized.After optimization,the regulation quality of primary air control system and the service life of boiler have been enhanced,the combustion in furnace being improved,the times of overtemperature for superheated and reheated steam,as well as the times of non-scheduled unit shutdown being greatly reduced,the consumption rate of service power being decreased,satisfying the requirement of power grid for load-reducing rate of unit.
作者 何映光
出处 《热力发电》 CAS 北大核心 2011年第9期62-64,共3页 Thermal Power Generation
关键词 300MW机组 CFB锅炉 一次风 控制 二次风 配风 高压流化风系统 300 MW unit CFB boiler primary air control secondary air air distribution high-pressure fluidized air system
  • 相关文献

参考文献2

二级参考文献7

共引文献57

同被引文献40

  • 1孔德奇,谷俊杰,李洋,田进.基于氧量软测量的锅炉在线燃烧优化控制[J].仪器仪表学报,2006,27(z1):530-532. 被引量:9
  • 2高洪培,王鹏利,张敏,孙献斌,徐正泉,王智微,王海涛,党黎军,张康道,蒋敏华.大型循环流化床锅炉临界流化风量控制与燃烧优化调整[J].热力发电,2005,34(4):31-33. 被引量:23
  • 3李建锋,吕俊复.风机流场的数值模拟[J].流体机械,2006,34(4):10-13. 被引量:64
  • 4GB18484-2001.危险废物焚烧污染控制标准[S].[S].,..
  • 5GB13223-2011.火电厂大气污染物排放标准[S].环境保护部:国家质量监督检验检疫总局,2011.
  • 6孙献斌,黄中.大型循环流化床锅炉技术与工程应用[M].2版.北京:中国电力出版社,2013:155-156.
  • 7杨敏媛.火电厂动力设备[M]北京:中国水利电力出版社,1996.
  • 8党黎军.循环流化床锅炉启动调试与安全运行[M]{H}北京:中国电力出版社,2002.
  • 9林万超.火电厂热系统节能理论[M]{H}西安:西安交通大学出版社,1994.
  • 10中国环境科学研究院固体废物污染控制技术研究所.液化残渣综合利用可行性论证报告[R].2014.

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部