摘要
为了研究探测器频带对光声成像分辨率的影响,采用有限元仿真实验,得出不同探测器频带与分辨率之间的经验公式,即对于mm量级的吸收体,探测器的截止频率大于2MHz时,重建图像分辨率变化不明显,当探测器的截止频率小于2MHz时,分辨率降低非常明显。该研究结果对光声成像探测器的选择、成像效果评估具有参考价值。
In order to research the influence of different bandwidths of transducer on photo-acoustic imaging resolution,finite element simulation experiments were carried out.An empirical formula was obtained between transducer bandwidth and photo-acoustic imaging resolution.Experimental results showed that the reconstructed image resolution of absorbers was unchanged in the order of millimeters when the cut-off frequency of transducer was greater than 2 MHz;however,it was contrary for the frequency less than 2 MHz.The results are helpful for the choice of transducer and the evaluation of image reconstruction.
出处
《应用光学》
CAS
CSCD
北大核心
2011年第5期831-834,共4页
Journal of Applied Optics
基金
陕西省科技厅基础研究项目(2011JM1016)
陕西省教育厅基础研究项目(2011JK0930)
关键词
医用光学与生物技术
光声成像
分辨率
不同探测器频带
medical optics and biotechnology
photo-acoustic imaging
resolution
different bandwidths of transducer