期刊文献+

铁碳床联合过氧化氢氧化-混凝技术深度处理制浆废水

Advanced Treatment of Pulp Effluent by Fe-C Bed Combined with Hydrogen Peroxide-coagulation
下载PDF
导出
摘要 采用铁碳床联合过氧化氢氧化-混凝技术对制浆造纸生化处理后的出水进行深度处理,考察了pH值、反应时间、H2O2投加量和进水水质等不同操作条件下对CODc,和色度去除的影响。结果表明,在pH值为5、反应时间为120min、H2O2投加量为100mg/L的条件下对污染物去除效果最佳,进水CODCr浓度对CODCr和色度去除影响不大。进水CODCr为520mg/L、色度为400倍情况下,出水CODCr低于100mg/L,色度低于50倍,出水各项指标均达到《制浆造纸工业水污染物排放标准》(GB3544-2008)。 The effluent from pulp mill after treatment by combined biochemical process can't meet the requirements of discharge standard because of high CODCr concentration and chroma. To solve the problem, Fe-C bed combined with hydrogen peroxide-coagulation process as advanced treatment under various conditions of pH, reaction time, dosage of H2O2 was investigated in this study. Results showed that the optimum operating conditions are as follows: pH value of initial influent 5, reaction time 120 min, H2O2 dosage 100 mg/L. The CODer concentration of initial effluent has little impact on CODc, and color removal. The CODCr concentration decreases from 520 mg/L to less than 100 mg/L, chroma decreases from 400 degree to less than 50 degree after treatment, which meets the national discharge standard of integrated wastewater discharge standard ( GB3544-2008 ).
作者 潘碌亭 余波
出处 《中国造纸》 CAS 北大核心 2011年第B08期48-52,共5页 China Pulp & Paper
关键词 制浆废水 深度处理 铁碳内电解 混凝 pulp effluent advanced treatment Fe-C internal electrolysis coagulation