期刊文献+

建筑遮阳在北京建筑工程中应用建议 被引量:3

SUGGESTIONS ON APPLICATION OF BUILDING SUNSHADE IN BEIJING ARCHITECTURAL ENGINEERING
下载PDF
导出
摘要 我国已发布的《公共建筑节能设计标准》(GB50189-2005)和《严寒和寒冷地区居住建筑节能设计标准》(JGJ26-2010)中,已对严寒和寒冷地区的公共建筑和居住建筑均规定了应对透光围护结构设置遮阳设施的要求。对于在北京地区采用遮阳设施的方式和遮阳装置的类型,根据北京地区气候特点进行了分析比较,提出了适用于北京地区居住建筑和公共建筑透光围护结构的遮阳装置类型。 Design Standard for Energy Efficiency of Public Buildings and Design Standard for Energy Efficiency of Residential Buildings in Severe Cold and Cold Zones have been promulgated in China. These Standards have specified that transparent enclosure structure of public buildings and residential buildings in cold zones shall be set with sunshade facilities. The mode and type of sun-shading facilities adopted in Beijing are analyzed and compared according to local climate in Beijing, and the type of sun-shading facility applicable to transparent enclosure structure of residential buildings and public buildings in Beijing is given.
出处 《建筑技术》 北大核心 2011年第10期882-885,共4页 Architecture Technology
关键词 建筑遮阳 外遮阳 内遮阳 中置遮阳 北京地区 building sunshade external sunshade intemal sunshade middle-positioned sunshade Beijing region
  • 相关文献

参考文献1

二级参考文献3

共引文献12

同被引文献18

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部