摘要
对应用于民用焦炉煤气加压系统的卧式罗茨风机出现的齿轮箱漏油、漏煤气等故障进行了全面分析,并提出具体可行的解决方法,有效解决了齿轮箱漏煤气导致漏油的问题。
An overall analysis was made on oil leakage and air leakage of horizontal Roots blower gear box for the pressurizing system of civil coke oven gas.The practical means of settlement were offered,which effectively solved the problem of oil leakage owing to air leakage of the gear box.
出处
《冶金动力》
2011年第5期25-26,共2页
Metallurgical Power
关键词
罗茨风机
漏气
漏油
齿轮箱
Roots blower
air leakage
oil leakage
gear box