期刊文献+

利用三光束激光干涉仪评估纳米平台的移动性能(英文) 被引量:4

Evaluation of nano-stage movement by using triple-beam laser interferometer
下载PDF
导出
摘要 纳米位移传感器多集成在纳米平台的平行移动柔性机构中,通过闭环控制回路来实现纳米级的平台移动精度,本文介绍了利用具有亚纳米分辨率的三光束单频激光干涉仪校正纳米级电容式线性移动平台位移的工作,阐述了校正测试系统的布局以及线位移和角度位移的校正测试原理。通过实验成功地对移动线位移320μm的纳米平台进行了校正,实验数据表明,该平台的偏摆最大角位移为3.5″。另外,对该校正系统进行了测量不确定度分析,在覆盖因子k=2时,它的扩展不确定度为(1.8+1.23×10-2 L)nm,测试长度L的单位是μm,由此显示该系统可有效评价纳米平台的移动性能。 Nanosensors are generally integrated into flexure translation stages to form a closed-loop feedback to control the movement of the stage accurately in a nano-scale order.To evaluate the displacement of nano-stages,a calibration system based on a single frequency triple-beam laser homodyne interferometer with a sub-nanometre resolution was developed to calibrate the precision of the linear nano-stage with a capacitive feedback sensor.The triple-beam configuration and its linear and angular measuring principles were described to reflect how the linear and angular displacements(yaw pitch) of the stage could be determined accurately.The experimental results demonstrate that the system is capable of calibrating the nano-stage with a linear displacement up to 320 μm and an angular deviation up to 3.5″.The error sources of the proposed calibration system were also highlighted in the measurement uncertainty analysis,and it shows that the expanded uncertainty of measurement with a coverage factor k=2 is estimated as(1.8+1.23×10-2 L) nm,where L is the displacement in μm.The results demonstrate that the proposed system can evaluate the movement performance of nano-stages efficiently.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2011年第9期2284-2292,共9页 Optics and Precision Engineering
基金 Nanometrology Roadmap Funded by Ministry of Industry and Trade in Singapore
关键词 电容式纳米平台 纳米位移传感器 激光干涉仪 capacitive nano-stage nanosensor laser interferometer
  • 相关文献

参考文献15

  • 1BOWEN D K, CHETWYND D G, SCHWARZEN BERGER D R. Sub-nanometer displacement calibration using X-ray interferometer Design [J]. Meas. Sci. Technol. , 1990,1:107-119.
  • 2YACOOT A, KUETGENS Us, KOENDERS L,et al.. A combined scanning tunneling microscope and x-ray interferometer [J]. Meas. Sci. Technol. , 2001,12:1660-1665.
  • 3DOWNS M J, NUNN J W. Verification of the subnanometric capability of an NPL differential plane mirror interferometer with a capacitance probe[J]. Meas. Sci. Technol. , 1998,9:1437-1440.
  • 4HAITJEMA H, SCHELLEKENS P H J, WET- ZELS. Calibration of displacement sensors up to 300μm with nanometre accuracy and direct traceablity to a primary standard of length[J]. Metrologia, 2000,37 : 25- 33.
  • 5LAWALL J R. Fabry-Perot metrology for displacements up to 50 mm[J]. J. Opt. Soc. Am. , 2005, 22:2786-2798.
  • 6BRAND U, HERRMANN K. A laser measurement system for the high-precision calibration of displacement transducers[J]. Meas. Sci. Technol. , 1996, 7:911-917.
  • 7TOM T B, LEE J Y, KIM J W,etal.. Portable calibration system for displacement measuring sensors [J]. International Journal of Precision and Manufacturing, 2006,7 (2): 56-59.
  • 8PICOTO O B. Interferometric calibration of microdisplacement actuators[J]. Proceeding of SPIE, 2003,5190 : 355-360.
  • 9PUPPIN E. Displacement measurements with resolution in the 15 pm range[J]. Rev, Sci. Instrum. , 2005,76:105107.
  • 10JAGER G. Laser-based measurement to nanometer scale accuracy[J]. SPIE, 2001,4420 : 193-202.

同被引文献35

  • 1所睿,范志军,李岩,张书练.双频激光干涉仪技术现状与发展[J].激光与红外,2004,34(4):251-253. 被引量:50
  • 2刘晓旻,吴宇,张攀峰,杨国光.光杠杆式nm级微位移激光测量系统的研究[J].光电子.激光,2006,17(8):969-973. 被引量:5
  • 3程维明,葛轶君.精密定位中的激光干涉测量误差分析[J].上海工程技术大学学报,2006,20(4):287-290. 被引量:11
  • 4Smith A R, Gwo S, Shih C K. A new high-resolution two-dimensional micropositioning device for scanning probe microcopy applications [ J ]. Review of Scientifw Instrumena,,1994, 65(10) :3 216 -3 219.
  • 5Garratt J D, Bottomley S C. Technology transfer in the development of a nanotopographic instrument [ J ] . Nanotechnology, 1990, 1 (4) : 38 -43.
  • 6Yeh H C, Ni W T, Pan S. Digital closed-loop nanopositioning using rectilinear flexure stage and laser interferometry [ J ]. Control Engineering Practice, 2005, 13(5) : 559 -566.
  • 7Haitjema H, Schellekens P H J, Wetzels S F C L. Calibration of displacement sensors up to 300 txm with nanometer accuracy and direct traceablity to a primary standard of length [ J ]. Metrologia, 2000, 37 ( 1 ) : 25 - 33.
  • 8Edlen B. The Refractive Index of Air [ J ]. 1966, 2(2) :71 -80.
  • 9王广宇,金星,叶继飞.激光干涉仪测微冲量原理[J].推进技术,2007,28(5):530-533. 被引量:6
  • 10Keysight Technologies. 5530 Dynamic Calibrator Data Sheet[R]. Santa Rosa, 2014.

引证文献4

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部