CT肺动脉血管成像体质量相关个体化管电流-时间的设置 被引量:3

CT Pulmonary Angiography:Body Weight Personalized Tube Current Product Scanning Protocol
下载PDF
导出
摘要 【目的】探讨多层螺旋CT肺动脉血管成像(MDCTPA)根据体质量个体化调节管电流的可行性及体质量相关的最佳管电流-时间设置。【方法】90例临床怀疑肺动脉栓塞(PE)的患者接受了MDCTPA检查,前瞻性、随机分为6组,每组15例。比较各组图像质量主观评分、客观评价及有效吸收剂量。【结果】各组图像主观评价差异有统计学意义(P=0.008)。各组患者的有效吸收剂量差异有统计学意义(P<0.01)。C组图像与F组图像比较,图像客观评价与主观评分差异均没有统计学意义,而C组有效吸收剂量均值较F组降低47.8%。【结论】MDCTPA根据体质量个体化调节管电流-时间是可行且有效的,取"1.0mA.s/kg"作为临床指引进行个体化管电流-时间调节,能很好地平衡图像质量与有效剂量的关系。 [Objective] To assess the feasibility of individual-adapted tube current-time scanning protocol for multiple detector row computed tomography pulmonary angiography(MDCTPA).[Methods] Ninety patients with suspected pulmonary embolism(PE) accepted MDCTPA examination.All patients were randomized divided into 6 groups(15 each).Objective and subjective image quality and effective dose(ED) were assessed and compared in these groups.[Results] The differences of subjective image quality scores and Effective dose(ED) in these 6 groups were significantly different(P = 0.008,P 0.01,respectively).There were no significant differences between group C and group F in objective/subjective parameters.The mean value of ED in group C was reduced by 47.8% than group F.[Conclusion] An individually adapted scanning protocol of MDCTPA using tube current-time based on patient's body weight could be effectively performed in clinical setting.With the tube current-time of 1.0 mA·s/kg,balance between the image quality and reduction of radiation exposure could be achieved.
出处 《中山大学学报(医学科学版)》 CAS CSCD 北大核心 2011年第4期511-514,共4页 Journal of Sun Yat-Sen University:Medical Sciences
基金 广东省自然科学基金(8151008901000210)
关键词 X线断层扫描仪 血管造影术 辐射剂量 computed tomography pulmonary angiography radiation dosage
  • 相关文献

参考文献12

  • 1Stein PD, Kayali F, Olson RE. Trends in the use of diagnostic imaging in patients hospitalized with acute pulmonary embolism [J]. Am J Cardiol, 2004, 93(10): 1316-1317.
  • 2Kuriakose J, Patel S. Acute pulmonary embolism [J]. Thorac Surg Clin, 2010, 20( 1 ) : 129-148.
  • 3Winer-Muram HT, Rydberg J, Johnson MS, et al. Suspected acute pulmonary embolism: evaluation with multi-detector row CT versus digital subtraction pulmonary arteriography [J]. Radiology, 2004, 233 (3): 806-815.
  • 4Blachere H, Latrabe V, Montaudon M, et al. Pulmonary embolism revealed on helical CT angiography : comparison with ventilation-perfusion radionuclide lung scanning [J]. Am J Roentgenol, 2000, 174(4) : 1041- 1047.
  • 5郑钧正,贺青华,李述唐,岳保荣,王琪,杨霞,张建峰.我国电离辐射医学应用的基本现状[J].中华放射医学与防护杂志,2001,21(S1):13-20. 被引量:64
  • 6周旭辉,彭振鹏,郑丽丽,李树荣,杨智云,孟悛非,陈星.64层螺旋CT肺动脉成像低管电压设置结合个体化对比剂应用的对照研究[J].中华放射学杂志,2009,43(7):704-707. 被引量:48
  • 7Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, et al. CT angiography of pulmonary arteries to detect pulmonary embolism : improvement of vascular enhancement with low kilovoltage settings [J]. Radiology, 2006, 241(3) : 899-907.
  • 8Sigal-Cinqualbre AB, Hennequin R, Abada HT, et al. Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose [J]. Radiology, 2004, 231 ( 1 ) : 169-174.
  • 9Heyer CM, Mohr PS, Lemburg SP, et al. Image quality and radiation exposure at pulmonary CT angiography with 100-or 120Kvp protocol: prospective randomized study [J]. Radiology, 2007, 245(9) : 577-583.
  • 10Primak AN, McCollough CH, Bruesewitz MR, et al. Relationship between noise, dose, and pitch in cardiac multi-detector row CT [J]. Radiographics, 2006, 26 (6) : 1785-1794.

二级参考文献13

  • 1李连弟,鲁凤珠,张思维,牧人,孙秀娣,皇甫小梅,孙杰,周有尚,欧阳宁慧,饶克勤,陈育德,孙爱明,薛志福,夏毅.中国恶性肿瘤死亡率20年变化趋势和近期预测分析[J].中华肿瘤杂志,1997,19(1):3-9. 被引量:869
  • 2Schueller-Weidekamm C,Schaefer-Prokop CM,Weber M,et al.CT angiography of pulmonary arteries to detect pulmonary embolism:improvement of vascular enhancement with low kilovoltage settings.Radiology,2006,241:899-907.
  • 3Heyer CM,Mohr PS,Lemburg SP,et al.Image quality and radiation exposure at pulmonary CT angiography with 100-or 120 kVp protocol:prospective randomized study.Radiology,2007,245:577-583.
  • 4Takahashi M,Maguire WM,Ashtari M,et al.Low-dose spiral computed tomography of the thorax:comparison with the standarddose technique.Invest Rediol,1998,33:68-73.
  • 5Lucaya J,Piqueras J,Garcia-Pena P,et al.Low-dose high resolution CT of the chest in children and young adults:dose,cooperation,artifact incidence,and image quality.AIR,2000,175:985-992.
  • 6Diederich S,Lenzen H,Puskas Z,et al.Low dose computerized tomography of the thorax:experimental and clinical studies.Radiology,1996,36:475-482.
  • 7Huda W,Scalzetti EM,Levin G.Technique factors and image quality as functions of patient weight at abdominal CT.Radiology,2000,217:430-435.
  • 8Primak AN,McCollough CH,Bruesewitz MR,et al.Relationship between noise,dose,and pitch in cardiac multi-detector row CT.Radiographics,2006,26:1785-1794.
  • 9Ertl-Wagner BB,Hoffmann RT,Bruning R,et al.Multi-detector row CT angiography of brain at various kilovoltage settings.Radiology,2004,231:528-535.
  • 10殷蔚伯,田凤华,谷铣之.我国放射治疗人员及设备现状[J].中华放射肿瘤学杂志,1998,7(2):131-133. 被引量:21

共引文献110

同被引文献34

  • 1路鹤晴,朱国英,郭常义.多层CT辐射剂量与防护研究进展[J].中国医学计算机成像杂志,2007,13(4):301-307. 被引量:15
  • 2Huisman MV, Klok FA. Diagnostic management of clinically suspected acute pulmonary embolism.J Thromb Haemost, 2009, 7(suppll): 312-317.
  • 3Coppenrath E, Schmid C, Brandl R, et al. Spiral CT of the abdomen: weight-adjusted dose reduction. Rofo, 2001, 173 (1) :52-56.
  • 4WildbergerJE, Mahnken AH, Schmitz-Rode T, et al. Individually adapted examination protocols for reduction of radiation exposure in chest CT. Invest Radiol, 2001, 36 (10) : 604-611.
  • 5Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology, 2000, 217(2) :430435.
  • 6Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, et al. CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage setting. Radiology, 2006, 241 (3) :899-907.
  • 7Heyer CM, Mohr PS, Lemburg SP, et al. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120- k V p protocol: prospective randomized study. Radiology, 2007, 245(2) :577-583.
  • 8Primak AN, McCollough CH, Bruesewitz MR, et al. Relationship between noise, dose, and pitch in cardiac multi-detector row CT. Radiographics, 2006, 26(6) :1785-1794.
  • 9Tack D, De Maertelaer V, Petit W, et al. Multi-detector row CT pulmonary angiography: comparision of standard-dose and simulated low-dose techniques. Radiology, 2005, 236( I) : 318- 325.
  • 10Ertl-Wagner BB, Hoffmann RT, Bruning R, et al. Multi-detector row CT angiography of brain at various kilovoltage settings. Radiology, 2004, 231(2): 528-535.

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部