摘要
以阳城国际发电有限责任公司6×350MW机组为例,根据电厂汽水取样系统在线硅酸盐连续分析仪的组成及工作原理,分析了在线硅酸盐连续分析仪产生故障的原因,介绍了在线硅酸盐连续分析仪的维护经验。
Taking 6×350 MW unit of Yangcheng International Power Generation Co., LTD as an example and according to the components and working principles of online silicate continuous analyzer in the power plant's vapour-water sampling system, this paper analyzes the reasons of the failures of online silicate continuous analyzer, and introduces some maintenance experiences of online silicate continuous analyzer.
出处
《科技情报开发与经济》
2011年第26期184-186,共3页
Sci-Tech Information Development & Economy
关键词
在线硅酸盐连续分析仪
故障分析
维护经验
online silicate continuous analyzer
failure analysis